Installation instructions
Fig. 8
Leveling wall mounting bracket
2.
Fig. 9
Mounting the heater
18
1.
6720813634-28.1V
CAUTION:
Personal injury and property damage.
▶ Appliance must be installed vertically.
4.6
Venting
DANGER:
▶ Do not reduce the exhaust or combustion air vent pipe
sizes.
▶ Do not common vent with any other vented appliance or
stove.
▶ Do not use Type-B vent as the actual exhaust vent system
for the appliance.
DANGER:
Flue gas poisoning!
▶ Failure to vent the exhaust gases to the outside (see table 5
for proper material) may result in dangerous flue gases
filling the structure in which it is installed.
NOTICE:
▶ Installations resulting in negative pressure/back draft
require sealed combustion (twin pipe / concentric).
Damage caused from back draft, ie. freezing, are not
covered by warranty.
NOTICE:
Appliance malfunction!
▶ Protect the exhaust and inlet from leaves and debris by
installing a screen on the end of the termination. ¼" mesh
minimum opening is recommended on screen.
▶ Do not install the water heater in areas where dust and
chemicals like hair sprays, spray detergents, chlorine, may
accumulate.
Greentherm T9900 SE/i – 6 720 813 635 (2019/03)
Need help?
Do you have a question about the Greentherm T9900 SE 160 and is the answer not in the manual?