Fig. 7
Side view
For servicing access, a 2ft clearance is recommended to the
front cover.
TOP (A)
FRONT (B)
BACK
SIDES
FLOOR (C)
Table 4
Recommended minimum clearances
4

Installation instructions

4.1

Specialized tools

The following specialized tools may be required for installation:
Manometer
Multi-meter
Combustion Gas Analyzer
C 950/C 1050 (Pro TL 175 C/199 C) – 6 720 805 440 (2019/10)
Greentherm (Pro TL 175/199)
12"
1"
0"
1"
12"
4.2

Introduction

Please follow these instructions. Failure to follow
instructions may result in:
▶ Damage or injury.
▶ Improper operation.
▶ Loss of warranty.
DANGER:
▶ The water heater must be installed by a qualified installer in
accordance with these instructions. If improperly installed,
a hazardous condition such as explosion or carbon
monoxide poisoning could result. Bosch
Thermotechnology Corp. is not responsible for improperly
installed appliances.
Common installation practice is to first determine the venting/
combustion air point of termination, then design the piping
layout back to the heater.
4.3

Venting

DANGER:
▶ Do not reduce the exhaust or combustion air vent pipe
sizes.
▶ Do not common vent with any other vented appliance or
stove.
▶ Do not use Type-B vent as the actual exhaust vent system
for the appliance.
DANGER:
Flue gas poisoning!
▶ Failure to vent the exhaust gases to the outside (see table 5
for proper material) may result in dangerous flue gases
filling the structure in which it is installed.
Installation instructions
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 1050 esPro tl 175cPro tl 199c

Table of Contents