Bosch Greentherm T9900 SE 160 Installation And Operating Instructions Manual page 53

Indoor residential tankless water heaters, 160 000/199 000 btu- natural gas 160 000/199 000 btu - liquefied petroleum lp gas
Hide thumbs Also See for Greentherm T9900 SE 160:
Table of Contents

Advertisement

▶ Touch the symbol
Display blinks 3 times and return to P7 menu.
6.8.1 Gas conversion from NG to LPG
WARNING:
Fatal accidents!
Before any service or testing in the appliance,
▶ Turn off the appliance.
▶ Disconnect the power supply cord.
▶ Shut off the gas supply.
WARNING:
The gas type conversion must only be carried out by a qualified
contractor.
▶ Turn Off the appliance.
▶ Remove the front cover from the appliance (section 3.3.2).
▶ Remove the four screws that retain the cover plate to the
gas manifold, see fig. 48 (plate in grey color).
Fig. 48
Gas manifold
▶ Remove metal plate and seal.
▶ The 3 restrictor plates should be pre-assembled onto their
tray, but if loose in box, follow installation instructions, as
shown in Figs. 49 and 50 [1].
▶ Insert the LP conversion plate in the appropriate location
shown in Figs. 49 and 50 [2].
DANGER:
▶ All three flow restrictors and seal must be assembled
according to the Fig. 49, to assure correct appliance
performance.
Greentherm T9900 SE/i – 6 720 813 635 (2019/03)
.
Fig. 49
199kBTU appliance gas conversion kit
Fig. 50
160kBTU appliance gas conversion kit
▶ Tighten the four screws.
▶ Open the gas supply valve.
▶ Turn On the appliance.
Operation instructions
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greentherm t9900 se/i 199Greentherm t9800 se 199 000 btuGreentherm t9800 sec 199 000 btuGreentherm t9800 se 160 000 btuGreentherm t9900 se 190Greentherm t9900 se 199

Table of Contents