6.7

Water valves calibration

Water valve calibration must be done when main water valve or
bypass valve is replaced. Also required when electronic control
unit is replaced.
The water valve calibration process takes several minutes.
▶ Do not interfere with the appliance.
Only possible after access Technical Settings menu (
section 6.6).
6.7.1 MF main water valve auto calibration
▶ Open one hot water tap.
Before moving to the next step:
▶ make sure there is water flow.
▶ Access menu PA.
52
.
to exit.
to scroll through other menus.
.
to exit.
.
▶ Touch symbol OK.
▶ Touch symbols
or
▶ Touch symbol OK.
The appliance will start the auto calibration of main valve.
Water flow will shut-off.
▶ Wait until indication of calibration completed appears on
the screen.
▶ Touch the symbol
6.7.2 BP bypass valve auto calibration
▶ Open one hot water tap.
Flow rate between 0.80 GPM and 1.80 GPM is required.
It's possible to confirm this value by entering BP bypass
water valve menu.
▶ Access menu PA.
▶ Touch symbol OK.
▶ Touch symbols
or
valve.
▶ Touch symbol OK.
The appliance will start the auto calibration of the bypass
valve.
The display shows the flow rate.
▶ You should adjust the flow rate at the beginning of the
calibration process.
▶ Wait for the indication that the calibration is completed to
appear on the screen.
▶ Touch the symbol
6.8

Gas type

Only possible after access Technical Settings menu.
▶ Access to menu P7 Gas Type.
Display shows appliance gas type.
▶ Use the symbols
WARNING:
The gas type conversion must only be carried out by a qualified
contractor.
Greentherm T9900 SE/i – 6 720 813 635 (2019/03)
to select MF main valve.
to return to main menu.
to select BP bypass water
to return to main menu.
or
to confirm gas type.