Key to symbols and safety instructions
H WARNING:
▶ To ensure that the water heater
functions properly, follow these
installation and maintenance
instructions.
▶ Never close the blow-off line of the
T&P safety valve. For safety reasons,
water may escape during heating.
H DANGER:
Risk of explosion!
If you smell gas
▶ Turn off the gas shut-off valve.
▶ Open windows and doors.
▶ Do not try to light the appliance.
▶ Do not touch any electrical switch,
telephone, and do not use outlets.
▶ Extinguish all open flames. Do not
smoke! Do not use lighters!
▶ Warn all occupants of the building. Do
not ring doorbells!
▶ If you can hear gas leaking, leave the
building immediately.
▶ Prevent others from entering the
building and notify the police and fire
department from outside the
building.
▶ From outside the building, call the gas
utility company and a trained and
certified installer.
H DANGER:
If you smell flue gas inside the house
▶ Switch off the appliance.
▶ Open windows and doors.
4
▶ Inform the certified installer who
installed the appliance to change
appliance installation location.
H DANGER:
Risk of poisoning!
Insufficient ventilation may cause
toxic flue gas to escape
▶ Never close off or reduce the size of
the air intake and outlet openings.
▶ The appliance must not be operated
until any obstructions have been
removed.
▶ Inform the customer of the problem
and the associated dangers.
H DANGER:
Danger from escaping flue gases
▶ Ensure all vent pipes and chimneys
are not damaged or blocked.
▶ Connect only one appliance to each
vent system or chimney liner.
▶ The venting system piping must not
feed into another air extraction duct.
▶ Do not route the flue system piping
through or inside another air
extraction duct.
H DANGER:
Danger of explosion of flammable
gases
▶ Work on gas components may only be
carried out by a trained and certified
installer.
Greentherm T9900 SE/i – 6 720 813 635 (2019/03)