Session Timeout Functions

By default, a user is never logged off automatically unless the value for the logon
session timeout is manually changed.
If the value for logon session timeout has been changed, the console starts a
timer after a user logs in and monitors the user's activities. If a user is idle for
more than a set duration, the console logs the user out automatically.
NOTE:
not required. The logon session for these users never times out unless a user
explicitly sets the idle time limit.
Change Session Timeout Duration
To change the duration for the logon session timeout, issue the
SETLOGOFFIDLETIME command.
Change Login Failure Count
To change the value for the logon failure count, issue the SETLOGINATTEMPTS
command.
Reference Guide – DOC. 7150B
For dynamic transport users (console symbol), console authentication is
Syntax: SETLOGOFFIDLETIME [minutes]
minutes: The duration (in minutes) that must elapse before the
o
console logs off an idle user. Entering 0 disables the user from being
logged off automatically. The default value is "infinite."
No parameter: Displays the current timeout setting
o
Example: SETLOGOFFIDLETIME 30
Syntax: SETLOGINATTEMPTS [number]
number: The number of login attempts allowed before the console is
o
blocked. Entering 0 allows unlimited attempts. The default value is "3."
No parameter: Displays the current setting
o
Example: SETLOGINATTEMPTS 3