Prepare the Control Subnet

Before enabling the Control Subnet on the control system, note the following
assumptions:
To prepare the Control Subnet:
1.
2. When prompted, enter a username and password for the administrator
3. Issue the reboot command to reboot the device with the new
4. Create other users and assign them to groups as needed. For more
5. Issue the CIPHER STRONG command to update the SSH ciphers setting.
6. Issue the SSHPORT OFF command to disable SSH.
7. If the installation requires Banners, copy the Banner to the following
At this time, FTP and HTTP services will be disabled. HTTPS will continue to be
available.
34 • 3-Series Control Systems
The system is not capable of dual authorization.
Physical security is assumed to be provided by the environment.
Administrators are trusted to follow and apply all administrator guidance
as needed.
Issue the AUTH ON command from the control system console over a
secure connection protocol (SSL/TCP, SSH, USB).
account. The password must be at least six characters.
CAUTION:
Do not lose the username and password for the administrator
account. The control system cannot be accessed without this information
after an administrator account has been created.
authentication settings.
information, refer to "User and Group Management" on page 10.
device folder: "\SSHBanner\banner.txt".