Out of the box, the device ships with the following local user groups with the
associated rights:
Default Rights of Local Groups
Crestron Admin
Crestron Programmer
Crestron Operator
Crestron User
Crestron Connect

Password Management

The following sections explain how to manage passwords for local users on the
control system.
Set Password Policy
To set the password policy for the control system, issue the SETPASSWORDRULE
command.
All passwords that are created, updated, or reset for local users must follow the
password rules set by this command to be considered valid.
14 • 3-Series Control Systems
GROUP
1
2
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
Syntax: SETPASSWORDRULE {-ALL | -NONE} |
{-LENGTH:minPasswordLength} {-MIXED} {-DIGIT} {-SPECIAL}
-ALL: All password rules are applied.
o
-NONE: No password rules are applied.
o
-LENGTH: Specifies the minimum password length. By default, the
o
minimum password length is six characters.
-MIXED: Specifies that the password must contain a lower and upper
o
case character.
-DIGIT: Specifies that the password must contain a number
o
character.
-SPECIAL: Specifies that the password must contain a special
o
character.
NOTE:
The -LENGTH, -MIXED, -DIGIT, and -SPECIAL parameters
cannot be combined with NONE.
Example: SETPASSWORDRULE -LENGTH:9 -MIXED -DIGIT -SPECIAL
3
4
5
6
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
No
Yes
No
No
Yes
No
No
No
No
No
Yes
No
No