Removal Procedures
2. Release the two tabs (A) securing the keypad to the keypad to the tub assembly.
4
3. Disconnect the UICC cable (B) from the operator panel PCB assembly.
4. Disconnect the two ribbon cables (C) from the operator panel PCB assembly.
5. Disconnect the ground (D) on the operator panel PCB assembly.
6. Tilt the operator panel keypad up and remove it from the machine.
Operator Panel Display Removal
1. Operator panel keypad.
2. Press the tab on the left side of the operator panel display and raise the operator panel display to
the up position.