Chapter 3
Maintaining the System
Identifying a Faulty Internal Drive
The system has internal-drive fault LEDs on the right-front handle (see
get an indication of the location of a failing drive.
Observe the internal-drive fault LEDs on the right-front handle.
Step 1
See
right half of the internal drive compartment, in row 3.
Open the right- or left-side cover and look at the fault LEDs on the drive trays.
Step 2
A solid amber fault LED indicates a failed drive.
Figure 3-8
1
2
The two columns of LEDs correspond to the two halves of the internal drive compartment (under
either the right- or left-side top cover).
The four numbered rows of LEDs correspond to the four horizontal rows of drive bays (14 drive bays
in each row).
Figure 3-8
for an example. In this example, the amber LED indicates that the failing drive is in the
Internal-Drive Status LED Example
1
2
3
4
3
Internal-drive fault LEDs on right-front handle of system,
indicating faulty drive in right side of row 3
Fault LED on drive carrier
1
4
3
2
1
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
Installing or Replacing System Components
Figure
3-1). Use these LEDs to
2
3 Front of system
3-19