Upgrading From S3260 With One M4 Server Node to S3260 With One M5 Server Node
This step only for setting static IPs (DHCP disabled)—Set the CMC and BMC internal IP addresses
Step 15
by using the Cisco IMC interface, as described in
page
2-18.
Use the Cisco IMC (GUI or CLI) to define hard drive zoning, which maps the hard drives to individual
Step 16
server nodes:
Using the Cisco IMC GUI:
Use the IP address of the CMC in either SIOC to log in to the Cisco IMC management software.
a.
Navigate to the following tab:
b.
Chassis > Inventory > Dynamic Storage > Zoning
Select the drives and then assign them to Server1 or Server2.
c.
Using the Cisco IMC CLI, enter the following commands with your choices:
Server# scope chassis
Server /chassis# scope dynamic-storage
Server /chassis/dynamic-storage# assign-drive <server ID> <drive-slotid-list>
For example:
Server# scope chassis
Server /chassis # scope dynamic-storage
svbu-huu-sanity-col2-1-vcmc /chassis/dynamic-storage # assign-drive server2 27
Are you sure you want to assign drives 27 to server2
Enter 'yes' to confirm -> yes
assign-drive operation successful.
If you want to add a second server node or SIOC to the system, continue with
Step 17
Node or SIOC to the S3260 System With M5 Server Node, page
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
E-6
Appendix E
Upgrading to Cisco UCS S3260 System With S3260 M5 Server Nodes
Setting Static CMC and BMC Internal IP Addresses,
Installing a Second Server
E-11.