Cisco UCS S3260 Service Manual page 103

Storage server chassis
Hide thumbs Also See for UCS S3260:
Table of Contents

Advertisement

Appendix E
Upgrading to Cisco UCS S3260 System With S3260 M5 Server Nodes
Open the Cisco IMC Configuration Utility:
Step 8
Press and hold the front panel power button for four seconds to boot the system. Watch the screen
a.
for the prompt to press F8.
During bootup, press F8 when prompted to open the Cisco IMC Configuration Utility.
b.
This utility has three windows that you can toggle between by pressing F1 or F2.
The utility prompts you to change the default user password. Set a default user password before
Step 9
continuing.
Set the CMCs in all SIOCs and the BMCs in all server nodes to the factory defaults.
Step 10
The Factory Default check box has two options but you must perform two resets in this order:
Select Chassis Controller Configuration and save your changes. Both CMCs in the SIOCs are set
a.
to the factory default state.
Select Server Controller Configuration and save your changes. The server node is set back to its
b.
factory default state and the server/host reboots.
Note
Note
When prompted, press F8 to enter the Cisco IMC Configuration Utility again.
Step 11
Set a new Cisco IMC password when prompted.
Step 12
Configure the management, CMC, and BMC IP addresses for the system.
Step 13
If you use a DHCP server and you already have QSFP cables attached to the SIOCs, the management IP
Note
address and network settings are already filled in. If you disable DHCP, you must set your own static
management IP address and network settings.
This step only for setting static IPs (DHCP disabled)—Set the CMC and BMC internal IP addresses
Step 14
by using the Cisco IMC interface, as described in
page
2-18.
Use the Cisco IMC (GUI or CLI) to define hard drive zoning, which maps the hard drives to individual
Step 15
server nodes. Use either the Cisco IMC GUI or the Cisco IMC CLI:
Using the Cisco IMC GUI:
Use the management IP address of the system to log in to the Cisco IMC management software.
a.
Navigate to the following tab:
b.
Chassis > Inventory > Dynamic Storage > Zoning
Select the drives and then assign them to Server1 or Server2.
c.
Using the Cisco IMC CLI, enter the following commands with your choices:
Server# scope chassis
Server /chassis# scope dynamic-storage
Server /chassis/dynamic-storage# assign-drive <server ID> <drive-slotid-list>
For example:
Upgrading From S3260 With Two M4 Server Nodes to S3260 With Two M5 Server Nodes
The BMC reboots after resetting to defaults. Watch for the prompt to press F8 when the server
reboots in the next step.
Set the BMC in the second server node to factory defaults also.
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
Setting Static CMC and BMC Internal IP Addresses,
E-9

Advertisement

Table of Contents
loading

Table of Contents