Removing CLAM
1. If possible, use lifter to move seat to uppermost position.
2.
Turn off mobility device.
3. Remove seat plate or sling seat (1). See 6.12 Seating, page 87.
4. Remove cover (2).
5. Pull all plugs out of lighting/actuator module CLAM.
6.
Loosen and remove relay. See Replacing relay in 6.6.5 Replacing and Calibrating True Track Plus Motor, page 31.
7. Loosen screws (1) with 3 mm Allen key and remove screws including CLAM mounting (2).
8. Replace lighting/actuator module CLAM (3).
When disassembling, take care of small parts such as screws and washers. Put all small parts down so that they
can be reassembled in the right sequence.
Installing CLAM
1. Refit parts in reverse order.
2. Plug all the plugs into their old positions.
3. Check all mobility device functions.

6.9.9 Replacing solid angle sensor bracket

Philips screwdriver
Removing solid angle sensor bracket
1. Loosen and remove screw B on stabilization bracket A.
2. Pull out solid angle sensor bracket C from under stabilization bracket.
3. Loosen and remove screws D.