TROUBLESHOOTING

6-1 TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
LEDs are not
illuminated.
Reversed battery polarity.
(transmitter/receiver)
Low battery indicator
blinks even though
the battery has
Reversed battery polarity.
been inserted.
(transmitter/receiver)
Reflection from the floor or wall.
Alarm is not
output.
Beam has not been blocked.
Channels of transmitter
and receiver are different.
Alarm is kept
Multiple photoelectric
detector for long distance
output.
or beam stacking applications.
Optical alignment was not
performed properly.
Batteries are going
Tamper button has not
flat too quickly.
performed properly.
Frost, snow or
Optical alignment not
heavy rain causes
optimized.
false alarm.
Improper output
The wiring is incorrect.
Screws between the
chassis and the back box
are loose.
Wall tamper does
not activate.
The waterproof packing on
back box is misplaced.
7

DIMENSIONS

7-1 DIMENSIONS
138 (5.4)
8
CORRECTIVE ACTION
Check the battery polarity.
Check the battery polarity.
Align beams away from the
floor or wall.
Block all four beams.
Set the same channel to
both transmitter and receiver.
Set channels 1-3 or 2-4 or
1-4.
See "4-2 OPTICAL
ALIGNMENT" on Page 9.
Set the cover or tamper
lock plate properly.
See "4-2 OPTICAL
ALIGNMENT" on Page 9
and make realignment.
Make correct wiring.
Tighten screws completely.
Remove chassis from the
back box and align the
waterproof packing onto
the chassis.
Unit: mm (inch)
EN-11

SPECIFICATIONS

8-1 SPECIFICATIONS
Model
SL-350QFR
Maximum detection range
100 m/350 ft.
Maximum arrival distance
1000 m/3500 ft.
Detection method
Quad infrared beam interruption detection
Selectable beam frequency
4 channels
Variable between 50/100/250/500 ms
Interruption time
(4 steps)
Recommend: 3.6 V, 13.0 Ah
Power source
LSH20 lithium batteries manufactured by SAFT
Operating range: 3.2 V - 4.0 V litium batteries
Transmitter: 2 or 4 units, Receiver: 2 or 4 units
745 µA
Transmitter: 420 µA + Receiver: 325 µA
Current draw
(at 25°C, 3.6 VDC)
Transmitter: Approx. 4 years
Battery life
*
Receiver:
**
Alarm output
Form C-Solid State Switch: 3.6 VDC, 0.01 A
Alarm period
2 sec (±1) (Nominal)
Form C-Solid State Switch: 3.6 VDC, 0.01 A
D.Q output
(Receiver only)
Output
N.C. (Solid State Switch): 3.6 VDC, 0.01 A
Low battery
output
Tamper output
N.C. (Mechanical Switch): 3.6 VDC, 0.01 A
(cover, back box,
Opens when cover, main unit
or back box is removed.
main unit)
Alarm indicator
Alarm: ON
(Receiver)
Light receiving: OFF
Level indicator
Not Light receiving: OFF
(Receiver)
Light receiving: Blinking or OFF
Indicator
Power indicator
Power ON: ON
(Transmitter)
Power OFF: OFF
Low battery indicator
Voltage reduction: Blinking
Operating temperature
-20°C - +60°C (-4°F - 140°F)
Operating humidity
95 % (max.)
Alignment angle
±90° Horizontal, ±10° Vertical
H х W х D mm (inch):
Dimension
452 (17.9) x 83 (3.3) x 138 (5.4)
3300 g (T otal weight of Transmitter +
Weight
Receiver, excluding accessories)
International protection
IP65
Specifications and design are subject to change without prior notice.
* The value is based on the condition that it is used within the
ambient temperature range of 20 to 25°C. (LSH-20 x2 pcs)
** Using batteries other than those recommended may shorten the battery life.
NOTE
These units are designed to detect an intruder and activate
an alarm control panel. Being only a part of a complete
system, we cannot accept responsibility for any damages
or other consequences resulting from an intrusion.
SL-350QNR
Approx. 5 years

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smart Line Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Sl-350 qfrSl-350 qnr

Table of Contents