Terminals; Parameter List - Mitsubishi Electric FR-A7AR Instruction Manual

Relay output function
Hide thumbs Also See for FR-A7AR:
Table of Contents

Advertisement

RELAY OUTPUT
4.2

Terminals

2A
1A
2B
1B
2C
1C
3A
3B
3C
*The operation of each relay depends on the output signal selected.
4.3

Parameter List

By installing this plug-in option, the parameters below are extended.
Set the values according to need.
Parameter Number
320
321
322
*1
For the FR-E700 series only, the initial value of Pr. 322 is "4".
Use Pr. 320 to Pr. 322 to select signals used for relay output. (Refer to page 22, 24 for signal types.)
REMARKS
• When an option alarm (
21
Terminal Symbol
1A
1B
1C
2A
2B
2C
3A
3B
3C
Name
RA1 output selection
RA2 output selection
RA3 output selection
to
) occurs, all outputs are tuned off.
Description
Relay RA1's normally open contact terminal
Relay RA1's normally closed contact terminal
Relay RA1's contact common terminal
Relay RA2's normally open contact terminal
Relay RA2's normally closed contact terminal
Relay RA2's contact common terminal
Relay RA3's normally open contact terminal
Relay RA3's normally closed contact terminal
Relay RA3's contact common terminal
Initial Value
0
1
2 (4)