Section 5 • Fault Codes
FAULT CODES
Code
Problem
363
MegaJector Internal
Actuator Fault Detection
364
MegaJector Internal
Circuitry Fault Detection
MegaJector Internal
365
Communication Fault
Detection
411
Coil Driver #1 Open
412
Coil Driver #1 Shorted
413
Coil Driver #2 Open
414
Coil Driver #2 Shorted
511
FPP1 High Voltage
512
FPP1 Low Voltage
513
FPP1 Higher than IVS Limit
514
FPP1 Lower than IVS Limit
521
FPP2 High Voltage
522
FPP2 High Voltage
531
TPS1 (Signal Voltage) High
532
TPS1 (Signal Voltage) Low
533
TPS2 (Signal Voltage) High
534
TPS2 (Signal Voltage) Low
535
TPS1 Higher than TPS2
536
TPS1 Lower than TPS2
537
Throttle Unable to Open
538
Throttle Unable to Close
545
Governor Interlock Failure
5 - 10
Cause
The MegaJector detects an internal fault. Open or
short in power, ground or CAN circuits.
The MegaJector detects an internal circuitry failure.
Open or short in power, ground or CAN circuits.
The MegaJector detects an internal
communications failure. Open or short in power,
ground or CAN circuits.
Open wiring and/or connections to ignition
coil #1 OR ignition coil #1 is faulty.
Wiring and/or connections to ignition coil #1
shorted OR ignition coil #1 is faulty
Open wiring and/or connections to ignition
coil #2 OR ignition coil #2 is faulty.
Wiring and/or connections to ignition coil #2
shorted OR ignition coil #2 is faulty
Not used.
The #1 throttle position sensor wiring and/or
connections open or shorted OR there is a poor
system ground connection OR throttle position
sensor #1 is faulty.
The #2 throttle position sensor wiring and/or
connections open or shorted OR there is a poor
system ground connection OR throttle position
sensor #2 is faulty.
The throttle position sensor wiring and/or
connections for either TPS1 or TPS2 open or
shorted OR there is a poor system ground
connection OR one or both throttle position
sensors are faulty.
Governor actuator is stuck closed OR wiring
and/or connections open or shorted OR
governor actuator is faulty.
Governor actuator is stuck open OR wiring
and/or connections open or shorted OR
governor actuator is faulty.
Engine harness wiring and/or connections open
or shorted OR there is a poor system ground
connection OR ECM is faulty.
S-40 • S-45
October 2013
Solution
Check Power, Ground and CAN circuits at
MegaJector and all connections and repair as
necessary OR MegaJector has an internal fault.
Contact Ford Power Products for assistance.
Repair wiring and/or connections to ignition
coil #1 OR replace ignition coil #1.
Repair wiring and/or connections to ignition
coil #2 OR replace ignition coil #2.
If this fault appears on your machine, contact
the Genie Industries Service Department.
Be sure system ground connections are in place
and secure OR repair wiring and/or connections
to sensor OR replace throttle position sensor #1.
Be sure system ground connections are in place
and secure OR repair wiring and/or connections
to sensor OR replace throttle position sensor #2.
Be sure engine harness wiring and connections
are in place and secure OR repair wiring and/or
connections to one or both TPS sensors OR
replace one or both TPS sensors.
Repair wiring and/or connections to governor
actuator OR replace the governor actuator.
Repair wiring and/or connections in engine
harness OR replace the ECM.
Part No. 102521