October 2013
4 Remove the turntable rotation assembly
mounting fasteners.
5 Carefully remove the turntable rotation assembly
from the machine.
Crushing hazard. The turntable
could rotate unexpectedly when
the rotation drive hub assembly is
removed if the turntable is not
secured with the turntable rotation
lock pin.
Crushing hazard. The turntable
rotation drive hub assembly could
become unbalanced and fall when
removed from the machine if not
properly supported.
When installing the drive hub assembly:
6 Install the drive hub. Apply Loctite
thread sealant and torque the backlash plate
mounting fasteners to 160 ft-lbs / 217 Nm.
Part No. 102521
®
removable
S-40 • S-45
Section 4 • Repair Procedures
TURNTABLE ROTATION COMPONENTS
4 - 57