Genie S-40 Service Manual page 167

Serial number range from s40-7001 to s4012-17231
Hide thumbs Also See for S-40:
Table of Contents

Advertisement

Section 5 • Fault Codes
FAULT CODES
Code
Description
261
FP (fuel pressure) high voltage
262
FP (fuel pressure) low voltage
271
FT (fuel temperature) gasoline high voltage
272
FT (fuel temperature) gasoline low voltage
273
FT (fuel temperature) gaseous fuel high voltage
274
FT (fuel temperature) gaseous fuel low voltage
311
Injector loop open OR low-side short to ground 1
312
Injector coil shorted 1
313
Injector loop open OR low-side short to ground 2
314
Injector coil shorted 2
315
Injector loop open OR low-side short to ground 3
316
Injector coil shorted 3
321
Injector loop open OR low-side short to ground 4
322
Injector coil shorted 4
351
FPump motor loop open OR high-side shorted to ground
352
Fpump motor high-side shorted to power
353
EPR delivery pressure higher than expected
354
EPR delivery pressure lower than expected
355
EPR comm lost
359
Fuel run-out longer than expected
361
EPR voltage supply high
362
EPR voltage supply low
363
EPR internal actuator fault detection
364
EPR internal circuitry fault detection
365
EPR internal comm fault detection
411
Primary loop open OR low-side short to ground 1
412
Primary coil shorted 1
413
Primary loop open OR low-side short to ground 2
414
Primary coil shorted 2
415
Primary loop open OR low-side short to ground 3
416
Primary coil shorted 3
421
Primary loop open OR low-side short to ground 4
422
Primary coil shorted 4
5 - 14
Code
531
TPS1 (throttle position sensor) high voltage
532
TPS1 (throttle position sensor) low voltage
533
TPS2 (throttle position sensor) high voltage
534
TPS2 (throttle position sensor) low voltage
535
TPS1 (throttle position sensor) higher than TPS2
536
TPS1 (throttle position sensor) lower than TPS2
537
Unable to reach higher TPS (throttle position sensor)
538
Unable to reach lower TPS (throttle position sensor)
539
TPS 1-2 simultaneous voltages
541
AUX analog PU1 high
542
AUX analog PU1 low
543
AUX analog PU2 high
544
AUX analog PU2 low
551
Max govern speed override
552
Fuel rev limit
553
Spark rev limit
611
COP failure
612
Invalid interrupt
613
A/D loss
614
RTI 1 loss
615
Flash checksum invalid
S-40 • S-45
October 2013
Description
Part No. 102521

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-45

Table of Contents