Genie S-40 Service Manual page 132

Serial number range from s40-7001 to s4012-17231
Hide thumbs Also See for S-40:
Table of Contents

Advertisement

October 2013
How to Set Up the Oscillate
Directional Valve
Note: Adjustment of the oscillate directional valve
linkage is only necessary when the linkage or valve
has been replaced.
1 Lower the boom to the stowed position.
2 Use a "bubble type" level to be sure the floor is
completely level.
Tip-over hazard. Failure to
perform this procedure on a level
floor could compromise the
stability of the machine resulting in
the machine tipping over.
3 Check the tire pressure in all four tires and add
air if needed to meet specification.
Note: The tires on some machines are foam-filled
and do not need air added to them.
4 Remove the drive chassis cover and the non-
steer axle covers.
5 Place a "bubble type" level across the drive
chassis non-steer end. Check to be sure the
drive chassis is completely level.
6 To level the drive chassis, start the engine and
loosen the lock nuts on both sides of the
urethane cushions.
Part No. 102521
7 Push up or pull down on the threaded rod until
the machine is completely level.
8 Verify that the ground and drive chassis are
completely level.
9 Tighten the nuts on both sides of the urethane
cushions until they are snug. Tighten the
locknuts.
10 Verify that the ground and drive chassis are
completely level.
11 Measure the distance between the drive
chassis and the non-steer axle on both sides
(from the inside of the drive chassis).
Note: If the distance is not equal and the
adjustment to the linkage was completed with the
ground and drive chassis level, repeat steps 6
through 11 OR consult Genie Industries Service
Department.
S-40 • S-45
Section 4 • Repair Procedures
MANIFOLDS
4 - 41

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-45

Table of Contents