Quick Links

SIMATIC IPC477E PRO
SIMATIC
Industrial PC
SIMATIC IPC477E PRO
Operating Instructions
08/2024
A5E39912462-AF
Preface
Overview
Safety guidelines
Mounting and connecting
the device
Commissioning the device
Operating the device and
device functions
Expanding the device and
assigning the device
parameters
Maintaining and repairing
the device
Technical specifications
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
9
A
B
C

Advertisement

loading
Need help?

Need help?

Do you have a question about the SIMATIC IPC477E PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens SIMATIC IPC477E PRO

  • Page 1 SIMATIC IPC477E PRO Preface Overview SIMATIC Safety guidelines Mounting and connecting the device Industrial PC SIMATIC IPC477E PRO Commissioning the device Operating the device and device functions Operating Instructions Expanding the device and assigning the device parameters Maintaining and repairing...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Connecting the 24 VDC power supply ................45 4.4.3 Connecting peripheral equipment ..................47 4.4.4 Connecting the device to networks ..................48 4.4.5 Installing the strain relief ....................49 4.4.6 Securing the cables ......................50 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 4 Changing the partitions under Windows 7 and Windows 10 ..........86 8.5.3 Installing drivers and software ................... 87 8.5.4 Update installation ......................87 8.5.4.1 Updating the operating system ..................87 8.5.4.2 Installing or updating application programs and drivers ............88 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 5 Opening the BIOS selection menu ..................130 9.7.3 Structure of the BIOS Setup menu ..................131 9.7.4 Exit menu ........................133 9.7.5 BIOS update ........................134 9.7.6 Alarm, error and system messages ................... 135 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 6 Markings and symbols ........................141 Overview ......................... 141 Safety ..........................141 Operator controls ......................141 Certificates, approvals and markings ................142 Interfaces ........................143 List of abbreviations .......................... 144 Glossary ............................. 149 Index ..............................157 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 7: Preface

    General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions apply to "SIMATIC IPC477E PRO" industrial PCs with article numbers 6AV7251-...-..Changes and additions to the manuals are documented in the product information.
  • Page 8 Approval for the hazardous area 02/2021 Fourth edition: • Approval for the hazardous area was removed from these operating instructions and documented in a product information. 08/2024 Fifth edition: • Update See also Product Information (https://support.industry.siemens.com/cs/ww/en/view/109744171) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 9: Overview

    The delivery note contains information on the precise scope of functions and product package for your device. The SIMATIC IPC477E PRO is available in the following device variants, which differ in regard to the display size, operating method and optional expansions:...
  • Page 10: Operating Systems

    Windows Embedded Windows Embedded terprise (64-bit) (32/64-bit) Standard 7 P (32-bit) Standard 7 E (32/64-bit) * WES7E is also supplied with IPC477E PRO devices. Multitouch is operated in single touch mode with WES7E. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 11: Installation

    Overview 2.2 Installation Installation Front view and side view ① ② Display with multi-touch screen ③ Enclosure ④ Backplane cover Terminal compartment cover Bottom view ① Mechanical interface for mounting/base adapter SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 12 Rear view - device version "prepared for support arm and extension components" ① Terminal compartment cover Note The device version "prepared for support arm and extension components" is intended for devices with an extension (see System components (Page 16)). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 13 Overview 2.2 Installation Bottom - device version "prepared for support arm and extension elements" ① Cover plate SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 14: Interfaces And Operator Controls For Pro Device

    3 × Ethernet interface (X1) P1, (X2) P1, (X3) RJ45 Ethernet port, 10/100/1000 Mbps ⑥ Connection terminal Connection terminal inserted in delivered condition ⑦ 24 V DC power supply (X80) ⑧ On/off switch Protective conductor connection SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 15: Accessory Kit

    System components for devices with all-round IP65 protection (https://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10299123?tree=CatalogTre SIMATIC IPC CFast cards • 2 GB optional or • 4 GB optional or • 8 GB optional or • 16 GB optional or • ≥ 30 GB optional SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 16: System Components

    See also Prepared for support arm or stand without extension elements (flange on top) (Page 33) Industry Mall (https://mall.industry.siemens.com) Expansion components and accessories (https://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10144445) System components for devices with all-round IP65 protection (https://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10299123?tree=CatalogTre SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 17: Round Tube Adapter

    ① ② Flange mount ③ Ring groove for fastening on PRO device with setscrews Mechanical interface to support arm Article number of the flange mount: 6AV7674-1KF00-0AA0 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 18: Adapter Set For Support Arm And Stand Mounting Of Pro Device

    Adapter set for support arm and stand mounting of PRO device The PRO device can be mounted on systems from third-party vendors (see section "Mounting the device (Page 32)"). For this you will need the Siemens base adapter (see Base adapter (Page 16)) and a proprietary adapter set.
  • Page 19: Extension Unit And Operator Controls

    • 15" • 19" • 22" • 24" For greater flexibility, three different connection options can be selected per size for the PLC connection of the operator controls: • Hardwired • PROFINET • PROFIsafe SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 20: Additional Information

    In addition, different operator controls such as emergency stop, selector switch, illuminated pushbutton, keyswitch, indicator light or RFID reader are available. Note Only operator controls with Siemens approval may be installed in the Extension Unit. You can find information on "System components for PRO device Extension Units" on the Internet (https://support.industry.siemens.com/cs/de/de/view/109742323/en).
  • Page 21: Safety Guidelines

    • Only install system expansion devices designed for this device. Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. • Read the information on electromagnetic compatibility (Page 92). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 22 When you touch electrostatic sensitive components, you can destroy them through voltages that are far below the human perception threshold. If you work with components that can be destroyed by electrostatic discharge, observe the ESD Guideline (Page 94). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 23: Industrial Security

    This product includes third-party software. Siemens Aktiengesellschaft only provides a warranty for updates/patches for the third-party software if such updates/patches have been distributed as part of a Siemens software update service contract or officially released by Siemens Aktiengesellschaft. Otherwise, updates/patches are undertaken at your own risk.
  • Page 24: Notes On Usage

    • Observe the permitted operating positions of the device. • Clean the enclosure surface with a damp cloth and make sure that no water enters the device. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 25: Lcd Displays

    A small number of defective pixels in the display is therefore unavoidable. This does not present a functional problem as long as the defective pixels are not bunched in one location. Additional information is available in the section "General technical specifications (Page 107)". SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 26: Mounting And Connecting The Device

    • Keep the original packaging. • Pack the device in the original packaging for transportation and storage. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 27 6. If the contents of the package are incomplete, damaged or do not correspond to your order, you can use the online form After Sales Information System (ASIS) (https://siemens.com/asis) to provide feedback on product deliveries and repairs. Complete the online form for product delivery (quality control notification) under the heading "Product delivery: Feedback on quality control and repairs".
  • Page 28: Device Identification Data

    Ethernet address 2 Ethernet address 3 Example of a SIMATIC IPC477E PRO rating plate COA label Microsoft Windows "Product Key" from the "Certificate of Authenticity" (COA): The COA label is present only when Windows Embedded Standard 7 or Windows 7 is installed.
  • Page 29 You usually do not need this product key for commissioning because a valid product key has already been integrated into the pre-installed operating system. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 30: Permitted Operating Positions

    Device version prepared for pedestal/extension components (flange at bottom) Operating Deviation from the vertical ① position ② Inclined ≤ 45° Vertical 0° SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 31 Device version prepared for support arm without extension components (flange at top) ① Operating position ② Inclined ≤ 45° Vertical 0° Device version "prepared for support arm and extension components (round tube)" ① Operating position ② Inclined ≤ 45° Vertical 0° SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 32: Mounting The Device

    Liability disclaimer The device is mounted to a pedestal or a support arm via the mechanical interface with screws. Siemens AG assumes no liability for the consequences of incorrect installation. Warranty at risk If you do not install the HMI device in accordance with the specifications in these operating instructions, the warranty for the device is voided.
  • Page 33: Prepared For Support Arm Or Stand Without Extension Elements (Flange On Top)

    Requirements • All packaging components and protective films have been removed. • Siemens base adapter with screws (supplied with the device version "prepared for support arm without extension components (flange at top)" and "prepared for pedestal/extension components (flange at bottom)").
  • Page 34 If you tighten the screws with a torque that is too low, the device is not sealed. 1. If an adapter plate for the Siemens base adapter is included in your support arm system, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
  • Page 35 7. Connect all cables according to the description in the section Connecting the device 8. Fasten the cover plate ⑤ to the device with the 2 screws, torque 1.5 Nm. (Page 40). Check that the seal is sitting correctly. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 36: Prepared For Support Arm And Extension Elements (Flange Mount)

    RS232. Procedure arm system using the optionally available Siemens flange mount ⑦. Mounting to a 48.3 mm The following description shows an example of how to attach the PRO device to a support round tube ⑧ that fits the opening of the PRO device is performed in a similar fashion.
  • Page 37 ⑧ Flange mount (not included in the product package; see System components (Page 16)) ⑨ Third-party round tube (∅ 48 mm) Cover plate (Included in the product package; see Accessory kit (Page 15)) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 38 Otherwise the device can become loose due to vibrations and drop. 4. If an adapter plate ⑨ for the Siemens flange mount is included with your support arm, attach the adapter plate to the support arm with 4 M6x12 screws. Pay attention to the torque that is specified for the support arm.
  • Page 39 9. Fasten the cover plate ⑨ from the PRO device product package with 4 M4x12 screws, seal is sitting correctly. torque 1.5 Nm. Alternatively, you can extend the PRO device by adding an Extension Unit at the bottom. Read the associated documentation. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 40: Connecting The Device

    • Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 41 Regenerative feedback of voltage to ground by a connected or installed component can damage the device. Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any voltage to the device. Regenerative feedback is generally not permitted. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 42: Power Supply

    Opening the terminal compartment cover Opening the terminal compartment cover for pedestal and support arm device versions without extension components. Opening the terminal compartment for device version prepared for support arm and extension components (round tube). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 43 If you tighten up the M4x16 screws with a torque of > 1.5 Nm, you may damage the threading in the enclosure. 3. Tighten the M4x16 screws of the terminal compartment cover using a maximum torque of 1.5 Nm. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 44: Connecting The Pe Conductor

    Tighten the M4 screw with a torque of max. 1.5 Nm. 3. Connect the protective conductor to the protective conductor connection of the control cabinet from which the PRO device is supplied. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 45: Connecting The 24 Vdc Power Supply

    • The corresponding 24 V DC power supply is switched off. • A two-core cable with a cable cross-section of ≥ 0.5 mm for the 24 V DC connection. • A slotted screwdriver with approx. 3 mm blade. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 46 The 24 V DC power supply is protected against polarity reversal. If you mix up the 24 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 47: Connecting Peripheral Equipment

    USB devices. Moreover, the terms of liability of the individual vendors or suppliers apply here. Note Strain relief Use the metal eyelets on the rear side to mount the cable strain reliefs for cable ties. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 48: Connecting The Device To Networks

    The software package and the documentation are not included in the product package. Additional information You can find additional information on the Internet at: Industry Mall, the ordering system for automation and drive technology (https://mall.industry.siemens.com) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 49: Installing The Strain Relief

    • Strain relief for USB and DisplayPort cable • Strain relief for LAN RJ45 cable Requirement • Strain reliefs • Screws • Screwdriver T10 Procedure Fasten the two strain reliefs to the device using the enclosed screws. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 50: Securing The Cables

    Procedure 1. Pass the cable tie around the respective strain relief bar and secure the cables as shown. ① Fastening with cable ties 2. Cut off the protruding ends of the cable ties. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 51: Commissioning The Device

    Configuring memory cards in the device Memory cards used in a device need to be configured on that device. Memory cards configured on other devices will not boot as the drive parameters will be different. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 52 • The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse Note Switching on the PRO device An external on/off switch is recommended to avoid having to continually open the terminal compartment cover. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 53: Initial Commissioning

    The product key is located on the "Certificate of Authentication", in the "Product Key" line. Result The interface of the operating system is displayed every time you turn on the device and after the startup routine. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 54 Additional information Information on your operating system can be found on the Internet: • Microsoft® Windows® 7 (https://support.industry.siemens.com/cs/ww/de/view/109749497/en?dl=en) • Microsoft® Windows® 10 (https://support.industry.siemens.com/cs/ww/de/view/109749498/en?dl=en) • Microsoft® Windows Embedded Standard® 7 (https://support.industry.siemens.com/cs/ww/de/view/109749499/en?dl=en) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 55: Windows Action Center

    Windows settings. You can then either acknowledge this warning or prevent the program from changing the Windows settings. This option is enabled for Windows 7 and Windows Embedded Standard 7 with the factory settings. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 56: Operating The Device And Device Functions

    Only touch the touch screen with your fingers or a suitable touch stylus. • On-screen keyboard • External keyboard, connected via USB • External mouse, connected via USB • Touch pen SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 57: Operating The Device

    Incorrect operation of devices with a touch screen can occur. This can result in personal injury or property damage. Take the following precautions: • Configure the plant so that safety-related functions are not operated with the touch screen. • Switch off the device for cleaning and maintenance. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 58: Notes On Operation

    – Surface contact with a diameter of > 3 cm, for example, resting the palm of the hand on the touch screen – As soon as the touch screen is no longer touched, input is possible again. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 59 • There is a conductive liquid on the touch screen with ground contact via the enclosure or the operator, for example. • Electromagnetic interference is present that exceeds the specification according to EN 61000-4-2. Once the interference is over, the touch screen is no longer locked. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 60: Panel Drivers And Tools Software

    • Download the software PDT V1.7 or higher from the Internet at: (https://support.industry.siemens.com/cs/ww/en/view/109792891) • The complete description of the functions for your device can be found along with the corresponding download file on the Internet at (https://support.industry.siemens.com/cs/ww/de/view/109974159/en). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 61: Extended Device Functions

    If a device is ordered with SIMATIC IPC DiagMonitor, the monitoring software SIMATIC IPC DiagMonitor is included with the device in the delivery state. Information on the software and documentation of SIMATIC IPC DiagMonitor can be found under: • SIMATIC IPC DiagMonitor (https://support.industry.siemens.com/cs/ww/de/view/39129913/en) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 62: Temperature Monitoring/Display

    A watchdog alarm is retained after a restart and is reset and logged by the DiagBase or DiagMonitor software. The watchdog configuration is retained in the process. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 63: Battery Monitoring

    When the first warning level is reached, the battery for buffering CMOS data still has a remaining service life of at least one month. 6.4.1.5 Mass storage monitoring The state of the SSD and CFast cards is monitored via SMART bit and reported by DiagBase or DiagMonitor. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 64: Unified Write Filter (Uwf)

    Proceed as follows to prevent this situation: • Make changes to storage media only when UWF is disabled. See also SIMATIC IPC Windows 10 User Manual (https://support.industry.siemens.com/cs/ww/de/view/109749498/en?dl=en) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 65: Enhanced Write Filter (Ewf)

    • "Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF Manager Configure the SIMATIC IPC UWF Manager with: • "Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF Settings • Click the "SIMATIC IPC EWF Manager" icon in the system tray.
  • Page 66 Start > Control Panel > Date and Time, remove the check mark from the "Automatically adjust clock for daylight saving changes" check box. 2. Save the change you have made with ewfmgr c: -commit and then reboot the system. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 67: File Based Write Filter (Fbwf)

    EWF and FBWF are pre-installed in the SIMATIC IPC images. Ensure that only one write filter is enabled on a partition, otherwise you risk data loss. Make sure that you only activate one write filter for each partition. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 68: Buffer Memory Nvram

    A memory window with a maximum size of 512 KB can be displayed by means of PCI address register. The base address is initialized by the BIOS. A corresponding function is implemented there for using the NVRAM under WinAC RTX and for using the CPU150xS SW controller. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 69: Trusted Platform Modul (Tpm)

    The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 70: Expanding The Device And Assigning The Device Parameters

    Expanding the device and assigning the device parameters Opening and closing the backplane cover Requirements • The device is disconnected from the power supply. • Torx TX20 screwdriver Opening the backplane cover SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 71 3. Remove the green connection terminal. The connection terminal is plugged in and can be 4. Loosen the eight M4x16 screws of the backplane cover ① (the screws are captive in the pulled out from the front. covers). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 72 The device may be damaged. 2. Pull out the cable connector ③ (see section "Replace SSD (Page 82)"). 3. Unplug the power supply connector ① on the motherboard. 6. Now you can install and remove the hardware. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 73: Installing And Removing A Memory Module

    The motherboard is equipped with one slot for an SO-DIMM DDR4 memory module. You can use it to expand the memory capacity of the device to a maximum of 16 GB. Note Use only the memory modules recommended by Siemens Aktiengesellschaft. You can find additional information in the section "Accessories (Page 15)". Requirements •...
  • Page 74: Installation

    1. Insert the memory module into the marked slot at an incline with the contact side toward the motherboard. 2. Carefully press the memory module into the contact strip until the latches engage. 3. Close the device. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 75: Installing And Removing A Cfast Card

    • Do not insert CompactFlash cards (CF cards) into the slot for the CFast card. • Always replace the SIMATIC IPC CFast card with a SIMATIC IPC CFast card of the same output version or higher. For the SIMATIC IPC477E PRO, only SIMATIC CFast cards with output version 02 or higher may be used.
  • Page 76: Assigning Cpu Power Consumption Parameters

    Same as standard, but additionally optimized for deterministic operation with optimized constant CPU frequency. Temperature Setting for lowest power consumption. optimized The CPU clock is limited at a higher load. The maximum power consumption of the CPU is 12 W. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 77: Maintaining And Repairing The Device

    Unauthorized opening and improper repairs on the device may result in substantial damage to equipment or endanger the user. If you install or replace a system expansion and damage your device, the warranty will become void. The device may only be repaired by qualified personnel. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 78 Do not recharge, open, or short lithium batteries. Do not reverse lithium battery polarity or heat the batteries to over 100°C. Keep lithium batteries out of direct sunlight and protect them from moisture and condensation. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 79: Limitation Of Liability

    UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 80: Cleaning The Device Front

    1. Switch off the device. 2. Dampen the cleaning cloth. 3. Clean the enclosure surface with the cleaning cloth and make sure that no water enters the device. 4. Clean the device with the cleaning cloth. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 81: Installing And Removing Hardware

    1. Remove the labeled connector. 2. The battery is fastened with a Velcro fas- tener. Grip the labeled battery and carefully pull it out. For installation, proceed in the reverse order and reconnect the device. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 82: Replace Ssd

    ④ of the power 3. Remove the indicated screws and firmly supply. 4. Remove the drive cage with the SSD and power supply and place it with the back facing up. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 83 • M3 x 5 countersunk screws for mounting the SSD drive in the drive cage Proceed in reverse order for the installation. 1. In step 1 above, ensure that the connectors are not installed with reverse polarity. 2. Close the device. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 84: Installing The Software

    The supplied USB flash drive contains the documentation, hardware drivers and updates. In Windows, these contents are available via a menu. Restore function If you have ordered IPC477E PRO with operating system, the supplied USB flash drive contains the Restore function. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 85: Partitioning The Data Storage Medium

    Remainder NTFS not compressed To restore the partitions to their original delivery state, we recommend you use the software SIMATIC IPC Image & Partition Creator. Additional information is available in the accompanying documentation. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 86: Partitioning In Windows 7 Ultimate

    1. Click in the partition manager with the right mouse button on the partition to be increased and click on "Increase size". 2. Follow the instructions on the screen. Additional information is available in the "Help" menu under "Help topics" and "Search". SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 87: Installing Drivers And Software

    Before you install new drivers or operating system updates for Windows MUI versions, configure the regional menu and dialog settings and the default English (US) language. other operating systems Contact the corresponding manufacturer. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 88: Installing Or Updating Application Programs And Drivers

    (images). The SIMATIC IPC Image & Partition Creator can be ordered using the Siemens online ordering system (https://mall.industry.siemens.com). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
  • Page 89: Technical Specifications

    Only the approvals specified on the device apply to the device itself. ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001:2008. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 90 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. BIS (India) This product meets the requirements of the Bureau of Indian Standard (BIS). Tested according to IS 13252(Part 1):2010/ IEC 60950-1 : 2005. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 91 Ambient conditions and installation guidelines The admissible environmental conditions and installation guidelines can be found in the certificates issued by the individual shipbuilding companies. After acceptance, the certificates are made available on the Internet (https://support.industry.siemens.com/cs/ww/en/ps/25042/cert?ct=446). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 92: Declaration Of Conformity

    CE marking The device meets the guidelines listed in the following sections. EU Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Panel PC certificates (https://support.industry.siemens.com/cs/ww/en/view/37369031). 9.2.2 Electromagnetic compatibility Electromagnetic compatibility This product meets the requirements of EC Directive 2014/30/EU "Electromagnetic Compatibility".
  • Page 93: Ukca Marking

    2012 (RoHS) : Marking on nameplate, if applicable UKCA Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: • Panel PC certificates (https://support.industry.siemens.com/cs/ww/en/view/37369031) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 94: Directives And Declarations

    The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 95 There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 96 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 97: Dimension Drawings

    Technical specifications 9.4 Dimension drawings Dimension drawings 9.4.1 Dimension drawing of 15" device with capacitive multi-touch screen Prepared for pedestal ① ② Without base adapter With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 98 Technical specifications 9.4 Dimension drawings Prepared for support arm ① ② Without base adapter With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 99 Technical specifications 9.4 Dimension drawings Prepared for support arm and extension components ① ② With flange mount Without flange mount All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 100: Dimension Drawing Of 19" Device With Capacitive Multi-Touch Screen

    Technical specifications 9.4 Dimension drawings 9.4.2 Dimension drawing of 19" device with capacitive multi-touch screen Prepared for pedestal ① ② Without base adapter With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 101 Technical specifications 9.4 Dimension drawings Prepared for support arm ① ② Without base adapter With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 102 Technical specifications 9.4 Dimension drawings Prepared for support arm and extension components ① ② Without flange mount With flange mount All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 103: Dimension Drawing Of 22" Device With Capacitive Multi-Touch Screen

    Technical specifications 9.4 Dimension drawings 9.4.3 Dimension drawing of 22" device with capacitive multi-touch screen Prepared for pedestal ① ② Without base adapter With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 104 Technical specifications 9.4 Dimension drawings Prepared for support arm ① ② Without base adapter With base adapter All dimensions in mm SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 105 Technical specifications 9.4 Dimension drawings Prepared for support arm and extension components ① ② Without flange mount With flange mount SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 106: Dimension Drawing Of 24" Device With Capacitive Multi-Touch Screen

    Technical specifications 9.4 Dimension drawings 9.4.4 Dimension drawing of 24" device with capacitive multi-touch screen Prepared for pedestal SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 107: Technical Specifications

    24 V DC power supply. Peak cur- rents greater than 6.5 A are possible. This will not have a negative impact on device functionality. not evaluated by UL SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 108 80% AM according to IEC 61000-4-3 3 V/m, 2.7 – 6 GHz 10 V, 10 kHz … 80 MHz according to IEC 61000-4-6 Immunity to magnetic fields 100 A/m, 50/60 Hz according to IEC 61000-4-8 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 109 2.5", ≥ 240 GB, SATA (optional) and 480 GB SATA (optional) CFast card 2 GB optional or 4 GB optional or 8 GB optional or 16 GB optional or ≥ 30 GB optional SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 110 MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example time- controlled via screen saver or centrally via PROFIenergy. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 111 MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example time- controlled via screen saver or centrally via PROFIenergy. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 112 Teaming can be set and initiated in the configuration interface. In teaming operation, jumbo frames, e.g. for the camera application, are not supported. The DisplayPort interfaces are compatible with DisplayPort V1.2. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 113: Environmental Conditions

    8.4 Hz to 500 Hz: 9.8 m/s Shock resistance, tested in accordance with IEC 60068-2-27, IEC 60068-2-29 Operation 50 m/s , 30 ms Storage/transport 250 m/s , 6 ms See also Permitted operating positions (Page 30) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 114: Power Requirements Of The Components

    The peak value of the starting current depends on the input voltage and the impedance of the 24 V DC power supply. Peak currents greater than 6.5 A are possible. This will not have a negative impact on device functionality. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 115: Restoring The Factory State Of The Software

    4. To boot from the USB flash drive, select the Boot Manager. 5. Select the USB flash drive in the Boot Manager and confirm the entry. 6. Select the Restore function and confirm the entry. 7. Follow the on-screen instructions. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 116: Windows

    4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Recovery function and confirm the entry. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 117: Setting Up The Language Selection By Means Of The Multilanguage User Interface (Mui)

    For this purpose, you can either select one of the preinstalled languages or install a new language package. The following command sequences are described in English. Depending on the default setting, they can be displayed in another language. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 118 1. Choose: "Start > Control Panel > Clock, Language, and Region > Regional and Language Options" 2. Select the "Keyboards and Languages" tab. 3. Click the "Install/uninstall languages" button and make the required changes. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 119 Technical specifications 9.5 Technical specifications The following languages can be installed at a later time: Language Windows German English French Italian Spanish Chinese (Hong Kong) Chinese (simplified) Chinese (Taiwan) Japanese Russian SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 120: Windows Embedded Standard

    Note the license terms of Windows Embedded Standard 7 Note the license terms for Windows Embedded Standard 7 and especially the extended software terms of the Siemens AG. You can find the license terms in the delivered document "MICROSOFT SOFTWARE LICENSE TERMS for Windows Embedded Standard 7"...
  • Page 121: Hardware Descriptions

    Short description Meaning Transmit data - (O) for full-duplex mode Transmit data + (O) for full-duplex mode Receive data + (I) for full-duplex mode Receive data - (I) for full-duplex mode Signal ground SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 122: Cfast (X50)

    PC10 Reserved Input/Output (not connected) PC11 Reserved Input/Output (not connected) PC12 Reserved Input/Output (not connected) PC13 Device Power (3.3V) PC14 Device Power (3.3V) PC15 Device GND PC16 Device GND PC17 Card Detect Out SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 123: Displayport (X70), (X71)

    Ground ML_Lane3- DP data 3- Output CONFIG1 CAD Cable Adapter Detect Input CONFIG2 Ground (PullDown) AUX_CH+ Auxiliary channel+ Bidirectional Ground AUX_CH- Auxiliary channel- Bidirectional Hot Plug Detect Input Ground DP_PWR +3.3V (fused) Output SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 124: Ethernet (X1) P1, (X2) P1, (X3) P1

    Output Data channel USB2 Input / output Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 125: System Resources

    High Definition Audio Controller PCI shared SATA AHCI Controller LAN1 (I219-LM) Graphics Management Engine Interface USB XHCI Controller IRQ17 PCIe-x4 slot on Riser (1x4) PCI exclusive IRQ18 PCIe-x4 slot on Riser PCI shared LAN2 (I210) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 126 Technical specifications 9.6 Hardware descriptions Interrupt Interrupt type IRQ19 LAN3 (I210) (optional) PCI exclusive IRQ20 Free IRQ21 Free IRQ22 Free IRQ23 Free SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 127: Input/Output Areas

    Watchdog enable register (read/write address 062h) Meaning of the bits Watchdog enable register (r/w address 062h) Meaning of the bits Watchdog enable bit (WDE) Watchdog circuit disabled Watchdog circuit enabled Watchdog Mode Standard Macro Reserved Reserved SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 128: Battery Status Register (Read Only, If The Rtc_Bat_Survey_En Address Is Set To "1"; 404Dh)

    NVRAM address register PCI register address: PCI register content: Length of the memory area NVRAM base address register NVRAM memory address (default) C2B0 0000 Address is assigned dynamically 80000 h (depending on device configura- tion) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 129: Bios Description

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 109781666 (https://support.automation.siemens.com/WW/view/en/109781666). SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 130: Opening The Bios Selection Menu

    The following message appears briefly after the device is switched on: Press ESC for boot options The BIOS selection setup appears: The number of buttons in the BIOS selection setup depends on your device version. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 131: Structure Of The Bios Setup Menu

    Configure hardware using different submenus Security Security functions, e.g., setting a password Power Specify power management of CPU and the device Boot Determine boot options, e.g., boot order Exit Save and exit (see Exit menu) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 132 Short help texts on the currently selected setup parame- ⑤ Key assignment ters are displayed in the center right-hand area. The key assignment for navigation in the BIOS Setup is found in the footer. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 133: Exit Menu

    Requirement: The parameters are saved prior to this with "Save Custom Defaults". Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 134: Bios Update

    Check regularly if updates are available for download (https://support.industry.siemens.com/cs/ww/en/view/109763408) to your device. Additional information can be found on the Internet at the following address: After Sales Informations System of SIMATIC PC (https://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
  • Page 135: Alarm, Error And System Messages

    CMOS battery is empty or not connected. Real-time clock has lost power The CMOS clock was operated without battery or with a battery that was too weak, during battery change, for example. Check the CMOS clock. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 136: Functional Scope In Windows

    Available Available Registry Filter Available Available Remote Assistance Available Available Remote Client Available Available Remote Desktop Available Available SIMATIC IPC DiagBase Available Available Speech Available Not available System Management Administrative Tools Available Available SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 137 Windows Security Center Available Available Windows Update Available Available Wireless Networking Available Available Note the licensing agreements for Windows Embedded Standard 7. Additional information on language selection is available in the section "Windows (Page 116)". SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 138: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://www.siemens.com/industrialsecurity) • Support request form (https://www.siemens.com/supportrequest) • After Sales Information System SIMATIC IPC/PG (https://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
  • Page 139: Problem Solving

    "chkdsk" is not function- EWF (Enhanced Write Filter) has been Deactivate the EWF or use an alternative method to activated. The "chkdsk" command is "chkdsk". not supported if the EWF has been activated. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 140: Notes On The Use Of Third-Party Modules

    • Signal frequencies or signal party expansion card was the cause of the fault. Replace this levels are not adhered to expansion card with a SIEMENS card or contact the card sup- • Different pin assignment plier. If the PC still crashes, contact your technical support team.
  • Page 141: Markings And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 142: Certificates, Approvals And Markings

    Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Peri- Approved for Korea od) marking for China Test mark of the Underwriters Labora- Disposal information, observe the tories local regulations. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 143: Interfaces

    Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 144: List Of Abbreviations

    Complementary metal oxide semiconductors tors Certificate of authentication Microsoft Windows Product Key Certificate of License License authorization Communications Port Term for the serial interface Communication Processor Communication computer Central Processing Unit Cathode Ray Tube SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 145 File Based Write Filter Floppy disk Disk drive, 3.5" Front Side Bus Ground Chassis ground Hard disk Hard disk High Definition Audio Hard Disk Drive Hard disk drive Height unit Human Machine Interface User interface SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 146 Syndicate of manufacturers of electrical compo- tion nents in the USA Non Maskable Interrupt Interrupt the processor can not reject NTFS New Techniques File System Secure file system for Windows versions (2000, XP, 7) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 147 Simple Network Management Protocol Network protocol SO-DIMM Small Outline Dual Inline Memory Module SafeCard on Motherboard (SOM) Standard Parallel Port Synonym for parallel port SRAM Static Random Access Memory Static RAM Solid State Drive SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 148 Program monitoring with error detection and alarming. WLAN Wireless LAN Wireless local area network Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 149: Glossary

    EC Directives, for example, with the EMC Directive. CFast card CFast is a digital storage medium in card form without moving parts. A CFast card uses the SATA protocol and its connectors are not compatible with a classic CompactFlash card. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 150 SETUP program. . Drivers Program parts of the operating system. They adapt user program data to the specific formats required by I/O devices such as hard disk, printers, and monitors. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 151 Refers to the central interface between the firmware, the individual components of a computer and the operating system. EFI is located logically beneath the operating system and represents the successor to PC BIOS, focusing on 64-bit systems. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 152: Hyper Threading

    Intel VT The Intel Virtualization Technology (IVT) is the implementation of a secure closed environment for applications. Special (visualization) software an a VT-capable processor is required for its use. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 153: Low Voltage Directive

    Legacy Boot Device Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 154: Plug And Play

    Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. Restart Warm restart of a computer without switching the power off (Ctrl + Alt + Del) SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 155: Troubleshooting

    This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 156: Trusted Execution Technology

    Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 157: Index

    Ethernet, 48 chkdsk, 139 Ethernet address, 28 Cleaning Agents, 80 Ethernet interface, 124 COA label, 28 EU Declaration of Conformity, 92 Components sensitive to electrostatic charge, 94 EWF (Enhanced Write Filter), 65 Condensation, 27 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 158 IPC477E PRO 19" Capacitive multi-touch screen, 57 Rear view, 12 Touch screen, 56 IPC477E PRO 19" Touch Main dimensions, 100, 101, 102 IPC477E PRO 22" Touch Main dimensions, 103, 104, 105 IT communication, 48 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 159 Transportation, 27 Safety instructions General, 21 Scope, 7 Warranty, 21 SCU, 131 Watchdog, 62 Serial number, 28 Enable register, 128 Setting up partitions Monitoring function, 62 Windows, 117 Monitoring times, 63 Trigger register, 127 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...
  • Page 160 Installation, 116 Windows 7 Ultimate Data backup, 88 Partitioning, 86 Windows Action Center, 55 Windows Embedded Standard Data backup, 88 Windows Embedded Standard 7 Setting up partitions, 85 Windows XP Professional Data backup, 88 SIMATIC IPC477E PRO Operating Instructions, 08/2024, A5E39912462-AF...