Input Chokes; Ac Input Chokes; Ac Output Chokes - gefran SIEIDrive ADV100 Quick Start Up Manual

Field oriented vector ac drive
Hide thumbs Also See for SIEIDrive ADV100:
Table of Contents

Advertisement

5.2 Input chokes

The three-phase mains choke is strongly recommended in order to:
-
limit the RMS input current of the ADV100 inverter.
-
increase the life of intermediate circuit capacitors and reliability of input diodes.
-
reduce the harmonic current distortion absorbed by the mains to typical values of 70% (at the rated current).
Mains chokes are optional from size 1040 to size 3220; on bigger sizes the choke is integrated in the DC link.

5.2.1 AC input chokes

Size
1040
1055
2075
2110
3150
3185
3220
To reduce the line current THD even more (< 35%), use DC chokes wired between terminals C1 and C.
Size
1040
1055
2075
2110
3150
3185
3220
Note!
Refer to the Gefran Accessories catalogue (1S9I09) for choke weights and dimensions.

5.3 AC output chokes

Output chokes are used to reduce dv/dt of power modules (IGBT). Voltage fronts can cause damage to motor isolation
systems or, if the motor cables are long (normally more than 100 m) or highly capacitive, they can cause drive malfunc-
tions and repeated signalling of overcurrent (OC) or desaturation (DESAT) conditions. The output chokes are listed in
the table below:
Sizes
1040
1055
2075
2110
3150
3185
3220
4300
4370
4450
5550
5750
5900
Note!
With the inverter operated at the rated current and a frequency of 50 Hz, the output chokes cause a voltage drop of approx. 2% of the output voltage.
Refer to the Gefran Accessories catalogue (1S9I09) for choke weights and dimensions.
22
THD (%)
(@400V/50Hz, with AC input chokes)
< 70 %
THD (%)
(@400V/50Hz, with AC input chokes)
< 35 %
Mains
Rated
inductance
current
(mH)
(A)
1,4
9,5
0,87
16
0,51
27
0,51
27
0,43
32
0,33
42
0,23
58
0,23
58
0,18
76
0,12
120
0,07
180
0,07
180
0,07
180
ADV100 • Quick installation guide - Specifications and connection
I
n
Model
(A)
LR3y-2040
9
13
LR3y-2055
16
LR3y-2075
LR3y-3110
22
30
LR3y-3150
38
LR3-022
LR3-022
45
I
n
Model
(A)
8
LDC-004
12
LDC-005
LDC-007
15
20
LDC-011
28
LDC-015
LDC-022
35
40
LDC-022
Saturation
current
(A)
20
34
57
57
68
72
100
100
130
205
310
310
310
Code
S7AAG
S7AB5
S7AB6
S7AB7
S7AB8
S7FF4
S7FF4
Code
S7AI10
S7AI11
S7AI12
S7AI13
S7AI14
S7AI15
S7AI15
Type
Code
LU3-003
S7FG2
LU3-005
S7FG3
LU3-011
S7FG4
LU3-011
S7FG4
LU3-015
S7FM2
LU3-022
S7FH3
LU3-030
S7FH4
LU3-030
S7FH4
LU3-037
S7FH5
LU3-055
S7FH6
LU3-090
S7F10
LU3-090
S7F10
LU3-090
S7F10

Hide quick links:

Advertisement

Table of Contents
loading