8.6.1 Alarm reset
•
If the alarm page is displayed:
Pressing the RST key, the alarms are reset and all alarms that have been reset are eliminated from the list. If, after
this operation, the list of alarms is empty, the alarm page is closed. If the list is not empty, press the ► key to exit
the alarms page.
•
If the alarm page is not displayed:
Press the RST key to reset the alarms. If active alarms are still present following reset, the alarm page is opened.
8.7 Messages
Operator messages are displayed with this page.
There are two types of messages:
- timed (closed automatically after a certain number of seconds),
- permanent (continue to be displayed until the operator presses the ESC key).
Several concurrent messages are enqueued and presented to the operator in sequence, starting from the most recent.
j
Message
k
Default param eters
l
Code:
m
Press ESC to exit
(1) Message: identifies a message.
xx indicates how many messages are enqueued. The queue may contain a maximum of 10 messages and the
message with the highest number is the most recent.
(2) Description of the message
(3) Sub-code of the message. Provides extra information in addition to the description.
(4) "Press ESC to exit" is displayed if the message requires acknowledgment.
When a message is closed, the next message is displayed until the queue is empty.
Note!
For further information, see
8.8 Saving and recovery of new parameter settings
Drive parameters can be saved on the keypad in 5 different memory areas. This function is useful for obtaining various
sets of parameters, for safety backup or transferring parameters from one drive to another.
8.8.1 Selection of the keypad memory
Note!
This example is only visible in Expert mode.
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 REFERENCES
Menu 04 DRIVE CONFIG, parameter 04.16 Keypad memory select, PAR: 594. The keypad features 5 memory areas
dedicated to saving parameters.
The memory to be used is selected using the Keypad memory select parameter. Subsequent saving and recovery
operations will be carried out on the memory selected.
52
01
0001H- 1
chapter
10.3.
04 DRIVE CONFIG
18/20
x3
Keypad memory select
Def:
ADV100 • Quick installation guide - Specifications and connection
PAR:
594
E
1
1
04 DRIVE CONFIG
18/20
PAR:
594
Keypad memory select
0000000002
Def:
1