A.2.1 Input/Output features
Digital inputs (DI) and enable hardware inputs (EN-HW)
Digital outputs (DO)
Relay outputs (RO)
Analog inputs (AI)
104
24V DC power supply
Tolerance
Maximum current
Isolation
Description
Type
Operating voltage
Load
Thresholds
Isolation
EN-HW
DI-X
+24V
Description
Type
Operating voltage
Load
Thresholds
Isolation
DO-X
Description
Type
Operating voltage
Load
Isolation
Description
Type
Input voltage
Input R
Resolution
Precision
Isolation
Description
Type
Input current
Input R
Resolution
Precision
ADV100 • Quick installation guide - Specifications and connection
Features
24 V PNP / NPN
0 V to + 24 V (+ 30 V max)
5 mA @ +24 V - R
V
ic
Yes – Functional (> 1 kV)
PNP
4k7
EN-HW
DI-CM
DI-X
Features
24V PNP / NPN
0V to + 24V (+ 30V max)
20mA @ +24V - R
V
ol
Si – Funzionale (> 1 kV)
PNP
DO-PS
+24V
DO-X
DO-X
LOAD
4k7
DO-CM
Features
NO Relay (single contact)
250 Vac / - 30 VDc / 2 A
50 mA @ +10 V
Yes – 4 kV
RO-X
Features
Voltage differential
± 10 V (± 12.5 V full scale)
10 kΩ
12 Bits (11 + sign)
1% of full scale
NO
Features
Current differential (AI2 only)
0 (4) mA to 20 mA
500 Ω
12 Bits (11 + sign)
1% of full scale
± 10%
150 mA
1 KV
= 4.7 kΩ
l
< 5 V – V
> 15 V
ih
NPN
EN-HW
DI-X
4k7
DI-CM
+24V
= 1,2 kΩ (40mA max)
l
< 1V – V
> V
-1
oh
ali
NPN
DO-PS
DO-X
4k7
DO-CM
RO-XO
RO-XC
EN-HW
DI-X
LOAD
+24V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents