Troubleshooting Tips Continued
Symptom
Erratic display
Manual overtemp
Tripping Frequently
60
Part # 8533-104-001 1/18
Probable Cause
Initial Start-up
Grounding
Program
Voltage spike
Recirculating
chamber Lint
Accumulation
Exhaust ducting
Excessive lint
buildup
Clean linto of
of top heat air
chamber above
tumbler
Suggested Remedy
If erratic on initial start-up, leave power
on for approximately one hour and check
machine operation again.
Machine must be grounded by separate
conductor back to neutral bar in breaker
box.
Check program and make corrections if
necessary.
Power down machine for 20 seconds
and repower. If no improvement, replace
control.
Remove manual overtemp thermostat
and inspect in chamber for excessive
lint build up. Access also gained to this
chamber by removing recirculation duct
mounted at bottom of chamber, or the
panel inside burner chamber between
burners and rear back panel
Remove exhaust duct at rear of dryer
and inspect for excessive lint build up in
complete duct from dryer to where duct
exits building.
Remove front panel completely. Be
careful of any wiring attached. Remove
heated air chamber cover and clean
above tumbler back to burner housing.