Troubleshooting Tips Continued
Symptom
Tumbler turns
but no spark
at burner
58
Part # 8533-104-001 1/18
Probable
Suggested Remedy
Cause
Glass fuse
Check small glass control fuse in back of dryer.
Replace if failed.
Temperature
The temperature sensor should have between
Sensor
30,000 ohms and 60,000 ohms resistance at
room temperature if okay. Replace if not in this
range.
Ignition
Check for 24VAC output from transformer.
Transformer
Replace if have 120V between black & white
and no 24V between red and yellow.
Over
Check to see if manually resettable thermostat.
Temperature
Thermostat is kicked out. Reset by pushing red
reset button.
Ignition control
Check for 24VAC coming into the control on the
at burner red wire. If voltage, then check for
24VAC out on the brown wire. Also check for
spark at the ignitor. If no 24VAC output or no
spark to the ignitor, replace ignition control.
Air Flow Switch
Check air flow switch to be sure it closes when
dryer is running. If not, adjust or replace
switch.
Hi-limit
Check for continuity. Should be 0 ohms
resistance when cold. If not, replace
thermostat.
Gas supply
No gas can cause system lockout
Electronic
Is electronic control closing gas relay to power
Control
Control heat circuit? Check for gas light on
electronic control. If no light change control. If
light is on, check voltage and components in
heat circuit at transformer at rear of unit.