Dexter Laundry T-350 Parts & Service Manual page 124

Commercial opl stack washer dryer
Table of Contents

Advertisement

F26
VFD unit has been added or
loose connection.
F27
Injection relay PCB has been
added to machine or loose
connection.
F28
Optional water valve PCB
has been added or loose
connection
NOTE: Whenever power is turned off to the washer, it must remain off for three minutes for
drive to reset. The washer will not operate correctly if this is done improperly. This will allow
most fault codes to reset that are displayed at washer front. A fault code F-13 or F-21 will
appear on front display if this procedure has not been reset correctly. Note: Should a power
loss occur during cycle and then power returns, P U S H will be displayed and customer must
push a temperature selection button to continue the cycle.
Motor
30lb 1ph or 3ph 60hz Main (wash & spin)
Dexter #9376-307-001
NOTE:
ing harness may be slightly higher.
124
Part # 8533-104-001 1/18
Drive Motor Inverter Type
Motor-Winding Resistance Chart
20lb C-Series Stack Washer
Winding
Resistance values are measured at the stator. Values at the end of the motor wir-
Soft reset control.
Soft reset control.
Soft reset control.
Wire #
T1 & T2
T2 & T3
T1 & T3
Resistance
Minimum
Maximum
3.91
4.60
3.91
4.60
3.91
4.60