Dryer Installation

All commercial dryer installations must conform with local applicable local codes or in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1A-1988. Canadian installations must comply with
current standard CAN/CGA-B149(.1 or .2) Installation Code for Gas Burning Appliances or Equipment, and
local codes if applicable. The appliance, when installed, must be electrically grounded in accordance with
the National Electric Code, ANSI/NFPA No. 70-1990,or when installed in Canada, with Standard CSA C22.1
Canadian Electrical Code Part 1.
Installation Clearances:
This unit may be installed at the following alcove clearances.
1. Left side-
2. Right side-
3. Back-
4. Front-
5. Top-
6. Floor-
Makeup Air

Adequate makeup air must be supplied to replace air exhausted by dryers on all types of installations.


Provide a minimum of 100 square inches of makeup air opening to the outside for each dryer. This is a

net requirement of effective area. Screens, grills, or louvers which will restrict the flow of air must be


considered. Consult the supplier to determine the free, area equivalent for the grill being used.

                   
The source of makeup air should be located sufficiently away from the dryers to allow an even air flow to
                  

the air intakes of all dryers. Multiple openings should be provided.





22

Part # 8533-104-001 1/18

0"
0"
18" (Certified for 1" clearance: however 18" is required to clean, service, and
maintain the dryer).
48" to allow use of dryer.
Refer to figure labelled "Vertical Clearance Dimensions".
This unit may be installed upon a combustible floor.
