Dryer Installation
All commercial dryer installations must conform with local applicable local codes or in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1A-1988. Canadian installations must comply with
current standard CAN/CGA-B149(.1 or .2) Installation Code for Gas Burning Appliances or Equipment, and
local codes if applicable. The appliance, when installed, must be electrically grounded in accordance with
the National Electric Code, ANSI/NFPA No. 70-1990,or when installed in Canada, with Standard CSA C22.1
Canadian Electrical Code Part 1.
Installation Clearances:
This unit may be installed at the following alcove clearances.
1. Left side-
2. Right side-
3. Back-
4. Front-
5. Top-
6. Floor-
Makeup Air
Adequate makeup air must be supplied to replace air exhausted by dryers on all types of installations.
Provide a minimum of 100 square inches of makeup air opening to the outside for each dryer. This is a
net requirement of effective area. Screens, grills, or louvers which will restrict the flow of air must be
considered. Consult the supplier to determine the free, area equivalent for the grill being used.
The source of makeup air should be located sufficiently away from the dryers to allow an even air flow to
the air intakes of all dryers. Multiple openings should be provided.
22
Part # 8533-104-001 1/18
0"
0"
18" (Certified for 1" clearance: however 18" is required to clean, service, and
maintain the dryer).
48" to allow use of dryer.
Refer to figure labelled "Vertical Clearance Dimensions".
This unit may be installed upon a combustible floor.