Temperature Testing
To check the temperature in the dryer tumbler, press and hold the start button and while holding the start
button also press the temperature button for the temperature to be checked. The display will read out the
current temperature.
20Lb Stack Washer/Dryer Temperature Sensor Removal
First remove Electronic Control. Once the control is removed, disconnect Temp Sensor wires by removing
the two gray wire nuts. Remove the two temp sensor mounting screws, 5/16 head, remove Temp Sensor
bracket assy. Remove sensor from bracket and replace and reinstall in reverse operation.
20Lb Stack Washer/Dryer Front Panel Removal
The loading door does not have to be removed to remove the front panels on this model.
1. Remove the left two screws with finish washers.
2. Remove the right two screws with finish washers, at this time the front panel is loose but
connected by the harness to the door switch.
NOTE:
Final Drive/Motor Belt Replacement
To replace the final drive belt turn the cylinder slowly by hand and work the belt off of the large pulley.
NOTE:
Tumbler Pulley Removal And Installation
Remove the 1/2" nut and lock washer. Pull the pulley off the shaft. Upon installation, the tumbler bolt
should be torqued to 75 ft./lbs.
1. On the set screws and torque to 165 in/lbs.
2. The Motor is mounted with 4 bolts to the motor mounting bracket on the rear of the dryer.
3. Reassemble in reverse ord
50
Part # 8533-104-001 1/18
Always remove power from the machine before changing drive belts or working with the
drive system.
All drive belts are self adjusting.