Available languages

R 01.04
Error Designation Possible Causes and Their Correction
111
112
113
114
115
125
129
130
180 to 243
251
255
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.1-7418
Timeout during initialization (MOBY I)
S The MDS is located in the boundary area of the read head.
S An MDS 507 is initialized but MDS 507 mode has not been
enabled under "Extras/MOBY I Setup."
The MDS memory cannot be read correctly (MOBY U).
S The MDS memory cannot be written and is defective.
S The OTP memory cannot be written again.
The address area of the MDS was exceeded.
S Check the memory size under "Extras/MOBY I Setup" or
"Extras/MOBY U Setup."
ECC error or MDS not initialized in ECC mode
S Enable ECC mode under "Extras/MOBY I Setup," and then
execute the INIT command.
Reset message after return of power
S The hand-held terminal has a defect in the power supply to
the read head. (Try charging/replacing the batteries.)
S The hardware of the read head has a defect.
Internal program error. Previous command is active.
The number of MDSs in the field is not permitted. Number of
MDS > multitag in the "SLG Status" function under "Extras."
Internal program error. The telegram layout of the command to
the read head is wrong.
Internal program error (MDS D1xx)
Turn the device off and on again. If error continues to occur,
contact Customer Support and specify the error number.
Read/write comparison not successful
No card/no MDS in the field