Siemens MOBY series User Manual page 78

Stg hand-held terminal
Table of Contents

Advertisement

Available languages

Available languages

Technical Data
Serial interface to PSION
S Transmission speed
S Transmission protocol
Interface for battery charging
S Voltage/current
S Charge duration
Operator control elements
Indication elements
S LED for charging the batteries
– On
– Not on
S LED for communication
– On
– Not on
Housing
S Color/material
Certifications
3 The operation time corresponds to the amount of time the antenna is on. For each MDS
function, this means the time from activation of the communication button to conclusion or
termination of the selected MDS function. If you do not point the hand-held terminal towards
an MDS after you press the communication button, the function is terminated after
30 seconds. The antenna is on during this time.
E-72
RS 232
115.2 kBaud
3964R
4-pin socket for connection of the STG U
power pack
12 V DC/1.225 A
> 1.5 h
(lithium ion battery pack 2SIP CGR18650 HG)
Communication button
(for triggering communication)
2 LEDs
Power pack connected
Red:
Device is defective.
Yellow: Batteries are being charged.
Green: Batteries are charged.
Power pack not connected.
Communication button pressed and communi-
cation not concluded
Red:
Battery capacity is not sufficient for
communication.
Yellow: Antenna is activated. Ready to
identify an MDS or identify an MDS
and communicate with it
Communication concluded or not started
Black/polyamide 6 GF 30
RF:
I-ETS 330440+C1:1997
SAR:
99/519/EG
Safety: EN 60950:2000
EMC:
EN 301489-01:2000
EN 301489-03:2000
ENV 50204:1995
FCC ID: NXWMOBYU-STGU
Safe for pacemakers
(5)J31069-D0126-U001-A5.1-7418
R 01.04
STG Hand-Held Terminal