The "Moby D/E/F/I/U" Programs - Siemens MOBY series User Manual

Stg hand-held terminal
Table of Contents

Advertisement

Available languages

Available languages

R 01.04
4

The "MOBY D/E/F/I/U" Programs

After you turn on the STG, the editor appears on the display. You can view the
data, enter new data or call a function with the "Menu" key. Functions can also
be called directly with the
ate alphanumeric key at the same time. The table below lists all functions to-
gether with their direct calls.
Command
File/Load File
File/Save
File/Exit
Tag/Read
Tag/Write
Tag/Erase/initialize
Tag/Tag status
Tag/Read TagId
Tag/Read OTP
Tag/Write OTP
Tag/Read raw data
Editor/Jump to address
Editor/Display
Editor/Clear
Editor/edit date
Extras/Communication
Extras/Password for STG
Extras/Address Setup
Extras/MOBY I Setup
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.1-7418
The "MOBY D/E/F/I/U" Programs
key. To do this, press the
Shortcut
Description
1
L or F3
Load file from PSION RAM drive to work-
ing storage
1
S or F4
Store read MDS data on the RAM drive
X
Exit STG application
1
R or F1
Read data from MDS
1
W or F2
Write data to MDS
E
Write MDS with a certain value
3
O
Read MDS status
T
Read ID number of MDS
3
F
Read data from OTP memory
3
H
Write data to OTP memory
2
M
Read physical memory of MDS
J or Tab
Jump to a certain address in editor
D
Change display options
C
Clear data in editor to a certain value
A
The date on which the cursor is posi-
tioned can be edited in a number of for-
mats.
I
Change communication options
P
Change password for STG application
G
Define entries for the "read/write MDS"
commands
H
Set memory size and MOBY I operating
mode
key and the appropri-
E-17