Error Designation Possible Causes and Their Correction
20
21
22 to 27
32
33, 34, 35, 36
37
38
39
40, 41, 42
43
45
50
52, 53, 54, 55,
56, 57
63
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.1-7418
S Reader device doesn't answer.
S Check parameters in the Extras/COMMUNICATION menu.
With SIM mode, "Interface" and "Protocol" must both be set
to SIM.
S Batteries in the reader device are empty. (The batteries
may be defective.)
Reader device doesn't answer at all or sends an incorrect
answer.
S Internal program error (MDS D1xx)
S Reader device sends the wrong answer.
S MDS is not personalized with the MOBY key.
S Internal program error (MDS D1xx/MDS F4xx)
Illegal request, internal program error
S Check contact to read head.
S Read device doesn't answer (MDS E6xx)
Internal program error
S Exit STG program, and start again.
S Read/write error (MDS F4xx)
S Read head gives you an error message.
S Read head is faulty.
S CRC error of MDS. Communication error to MDS. MDS is
located on the boundary.
S MDS has a defect.
S Internal program error
Specified block is write-protected.
Several MDSs are in the field.
S Internal program error (MDS D1xx)
Reader device doesn't answer at all or sends an incorrect an-
swer (MDS D1xx/MDS F1xx/MDS Uxxx).
S Internal program error (MDS D1xx)
S Check interface to MOBY U antenna (MDS Uxxx).
User termination with ESC
Wrong answer from read device
Error while reading or writing the MDS data
Internal program error on MOBY read head
Authentication error. The MDS doesn't have the MOBY key.
S Try setting the "B" key under "Extras/MOBY E Setup."
Error Messages