6. LW3 Programmers' Reference
6.6.4. Setting the Databit
Command and Response
SET•/MEDIA/UART/P1.DataBits=<databit>
Ý
pw•/MEDIA/UART/P1.DataBits=<databit>
Ü
Parameters
<databit>:
8 or 9
Example
Ý SET /MEDIA/UART/P1.DataBits=8
Ü pw /MEDIA/UART/P1.DataBits=8
6.6.5. Setting the Stopbits
Command and Response
SET•/MEDIA/UART/P1.StopBits=<stopbit>
Ý
pw•/MEDIA/UART/P1.StopBits=<stopbit>
Ü
Parameters
<stopbit>
0: 1
1: 1,5
2: 2
Example
Ý SET /MEDIA/UART/P1.StopBits=0
Ü pw /MEDIA/UART/P1.StopBits=0
6.6.6. Setting the Parity
Command and Response
SET•/MEDIA/UART/P1.Parity=<parity>
Ý
pw•/MEDIA/UART/P1.Parity=<parity>
Ü
Parameters
<parity>
0: no parity 1
1: odd
2: even
Example
Ý SET /MEDIA/UART/P1.Parity=0
Ü pw /MEDIA/UART/P1.Parity=0
HDMI20-OPTC series – User's Manual
6.6.7. Enabling Command Injection Mode
Command and Response
SET•/MEDIA/UART/P1.CommandInjectionEnable=<ci_enable>
Ý
pw•/MEDIA/UART/P1.CommandInjectionEnable=<ci_enable>
Ü
Parameters
<ci_enable>:
true: enabled
false: disabled
Example
Ý SET /MEDIA/UART/P1.CommandInjectionEnable=true
Ü pw /MEDIA/UART/P1.CommandInjectionEnable=true
ATTENTION!
The
Command
/MEDIA/UART/<P
>.CommandInjectionStatus.
1
injection
status
is
stored
in
another
read-only
52
property: