Warnings And Cautions - Cisco PA-MC-2T3+ Installation And Configuration Manual

Multi-channel t3 port adapter
Table of Contents

Advertisement

Chapter 3
Removing and Installing Port Adapters
The following is a functional description of OIR for background information only; for specific
procedures for installing and replacing a module in a supported platform, refer to the
Removal and Installation" section on page
Each module has a bus connector that connects it to the router. The connector has a set of tiered pins in
three lengths that send specific signals to the system as they make contact with the module. The system
assesses the signals it receives and the order in which it receives them to determine if a module is being
removed from or introduced to the system. From these signals, the system determines whether to
reinitialize a new interface or to shut down a disconnected interface.
Specifically, when you insert a module, the longest pins make contact with the module first, and the
shortest pins make contact last. The system recognizes the signals and the sequence in which it receives
them.
When you remove or insert a module, the pins send signals to notify the system of changes. The router
then performs the following procedure:
1.
2.
3.
Before you begin installation, read
Note
required for installation.

Warnings and Cautions

Observe the following warnings and cautions when installing or removing port adapters.
If a port adapter lever or other retaining mechanism does not move to the locked position, the port
Note
adapter is not completely seated in the midplane. Carefully pull the port adapter halfway out of the slot,
reinsert it, and move the port adapter lever or other mechanism to the locked position.
To prevent jamming the carrier between the upper and the lower edges of the port adapter slot, and to
Caution
ensure that the edge connector at the rear of the port adapter mates with the connection at the rear of the
port adapter slot, make certain that the carrier is positioned correctly, as shown in the cutaway in the
following illustrations.
When performing the following procedures, wear a grounding wrist strap to avoid ESD damage to the
Caution
card. Some platforms have an ESD connector for attaching the wrist strap.
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
Warning
when servicing.
OL-3526-05
Rapidly scans the system for configuration changes.
Initializes newly inserted port adapters or administratively shuts down any vacant interfaces.
Brings all previously configured interfaces on the module back to their previously installed state.
Any newly inserted interface is put in the administratively shutdown state, as if it was present (but
not configured) at boot time. If a similar module type is reinserted into a slot, its ports are configured
and brought online up to the port count of the originally installed module of that type.
3-4.
Chapter 2, "Preparing for Installation,"
PA-MC-2T3+ Multi-Channel T3 Port Adapter Installation and Configuration
Warnings and Cautions
"Port Adapter
for a list of parts and tools
3-3