Cisco PA-MC-2T3+ Installation And Configuration Manual page 123

Multi-channel t3 port adapter
Table of Contents

Advertisement

Chapter 5
Configuring Channelized mode for the Cisco PA-MC-2T3+
FREEDM version: 1, reset 0
Applique type is Subrate T3
Receiver has idle signal.
MDL transmission is disabled
FEAC code received: No code is being received
Framing is C-BIT Parity, Line Code is B3ZS, Clock Source is Line
Rx throttle total 0, equipment customer loopback
Data in current interval (287 seconds elapsed):
Total Data (last 24 hours)
T3 0/1/1 is down.
CT3 H/W Version: 0.1.1, CT3 ROM Version: 0.95, CT3 F/W Version: 1.3.2
FREEDM version: 1, reset 0
Applique type is Channelized T3
Receiver has loss of signal.
Framing is M23, Line Code is B3ZS, Clock Source is Internal
Rx throttle total 0, equipment customer loopback
Data in current interval (293 seconds elapsed):
Total Data (last 24 hours)
(additional displayed text not shown)
The following examples show command output display information for a PA-MC-2T3+ in port adapter
slot 0 on a VIP installed in interface processor slot 4.
show controllers T3 4/0/0 brief
Router# show controllers T3 4/0/0 brief
T3 4/0/0 is up.
(additional displayed text not shown)
OL-3526-05
0 Line Code Violations, 0 P-bit Coding Violation
25152 C-bit Coding Violation, 0 P-bit Err Secs
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs
0 Unavailable Secs, 0 Line Errored Secs
287 C-bit Errored Secs, 287 C-bit Severely Errored Secs
0 Line Code Violations, 0 P-bit Coding Violation,
7571467 C-bit Coding Violation, 0 P-bit Err Secs,
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
0 Unavailable Secs, 0 Line Errored Secs,
86400 C-bit Errored Secs, 86400 C-bit Severely Errored Secs
Hardware is 2CT3+ single wide port adapter
0 Line Code Violations, 0 P-bit Coding Violation
0 C-bit Coding Violation, 0 P-bit Err Secs
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs
293 Unavailable Secs, 0 Line Errored Secs
0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
0 Line Code Violations, 0 P-bit Coding Violation,
0 C-bit Coding Violation, 0 P-bit Err Secs,
0 P-bit Severely Err Secs, 0 Severely Err Framing Secs,
86400 Unavailable Secs, 0 Line Errored Secs,
0 C-bit Errored Secs, 0 C-bit Severely Errored Secs
Hardware is 2CT3+ single wide port adapter
CT3 H/W Version: 0.1.1, CT3 ROM Version: 0.95, CT3 F/W Version: 0.15.3
FREEDM version: 1, reset 0
Applique type is Channelized T3
No alarms detected.
FEAC code received: No code is being received
Framing is M23, Line Code is B3ZS, Clock Source is Internal
Rx throttle total 0, equipment customer loopback
PA-MC-2T3+ Multi-Channel T3 Port Adapter Installation and Configuration
Checking the Configuration
5-37