Paradox Digiplex DGP-848 Programming Manual page 40

Security and access control
Hide thumbs Also See for Digiplex DGP-848:
Table of Contents

Advertisement

Section #
Description
[900]
Display Serial Number of Control Panel and All Modules Connected to the Combus:
After entering section [900], the keypad will display the 8-digit serial number of the control panel:
For LCD Keypads: Use the [ ] and [ ] keys to scroll through the serial number of each module on the combus.
For Grafica keypads: Press the center action key (Next) to scroll through the serial number of each module on
the combus.
[950]
Reset System Master Code:
To reset the System Master Code to 123456 and reset the options to default, put the "reset" jumper to on and
enter section [950]. You do not have to remove power from the control panel.
[951]
Module Reset:
Reset a module's programmed contents to default by entering its serial number.
[952]
Locate/Unlocate Module:
Locate a specific module (e.g. detector, zone expander, etc.) connected to the combus by entering the
module's serial number. The green "
entered or the appropriate "tamper" or "unlocate" switch on the module is pressed.
[953]
Module Programming Mode:
Enter the serial number of the module you wish to program.
[954]
Module Broadcast:
Copy the contents of all programming sections from one module to one or more modules of the same type.
Enter the serial number of the source module, followed by the serial numbers of the modules you wish to
program. To begin transferring data, press [
keypads.
PLEASE NOTE: The Module Broadcast feature will only work when a module is broadcasting its data to a
module or to modules of the same type and model number. For example, an APR-PRT1 (Printer Module)
cannot broadcast to an APR3-PRT1. Likewise, a DGP module cannot broadcast to a DGP2 module.
[955]
Remove Modules:
After entering the section, the control panel will scan all modules connected to the combus. If any missing
modules are detected (i.e. detector removed from the combus), the control panel will erase the module's serial
number, removing the module from the control panel's memory.
Paradox Memory Key
[961]
Download from the Memory Key to control panel except sections [001] to [056].
[962]
Download from the Memory Key to control panel including sections [001] to [056].
[965]
Copy the control panel sections to the Memory Key except sections [001] to [056].
[966]
Copy the control panel sections to the Memory Key including sections [001] to [056].
Download Memory Key to Control Panel
1. Remove AC and battery power from the control panel you want to program.
2. Insert the Memory Key onto the control panel's connector labelled "
3. Re-apply AC and battery power.
4. To download the contents of the Memory Key except sections [001] to [048] (device serial
numbers) and [049] to [056] (Keyswitch serial numbers), enter installer programming mode, then enter section [961].
To download the contents of the Memory Key including sections [001] to [048] and [049] to [056], enter installer
programming mode, then enter section [962].
5. When the keypad emits a confirmation beep, wait 10 seconds and remove the Memory Key.
Copy Control Panel to Memory Key
1. Remove AC and battery power from the control panel you want to copy.
2. Insert Memory Key onto the control panel's connector labelled "
protect jumper is on.
3. Re-apply AC and battery power.
4. To copy the contents to the Memory Key except sections [001] to [048] (device serial numbers)
" LED on the module will begin to flash until the serial number is re-
LOCATE
ACC
Digiplex DGP-848
- 40 -
] on LCD keypads or the center action key (Start) on Grafica
".
DIGIPLEX KEY
". Ensure the write
DIGIPLEX KEY
Programming Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents