Zone Programming - Paradox Digiplex DGP-848 Programming Manual

Security and access control
Hide thumbs Also See for Digiplex DGP-848:
Table of Contents

Advertisement

When option [7] in section [502] is enabled for
PGM1 to act as a zone input for two-wire smoke
detectors, the control panel will recognize PGM1
as input number 255.
Zone
Description
1
________________ __________
2
________________ __________
3
________________ __________
4
________________ __________
5
________________ __________
6
________________ __________
7
________________ __________
8
________________ __________
9
________________ __________
10
________________ __________
11
________________ __________
12
________________ __________

Zone Programming

Zone Numbering
Sections [001] to [048] represent zones 1 through
48. This feature tells the control panel where the
detection device is connected and which of the 48
zones is assigned to that device.
Enter 3-digit [
INPUT NUMBER
Module to which the hardwired
detection device is connected.
NOTE: No input number is required
for Addressable Motion Detectors,
Keypad Zones or the Access Control
Module (DGP2-ACM1P).
Enter a 8-digit [
SERIAL NUMBER
the Addressable Detector or
Module to which the hardwired
detection device is connected.
Module
Section
8-digit Serial Number
[001]
__/__/__/__/__/__/__/__
[002]
__/__/__/__/__/__/__/__
[003]
__/__/__/__/__/__/__/__
[004]
__/__/__/__/__/__/__/__
[005]
__/__/__/__/__/__/__/__
[006]
__/__/__/__/__/__/__/__
[007]
__/__/__/__/__/__/__/__
[008]
__/__/__/__/__/__/__/__
[009]
__/__/__/__/__/__/__/__
[010]
__/__/__/__/__/__/__/__
[011]
__/__/__/__/__/__/__/__
[012]
__/__/__/__/__/__/__/__
Zone Parameters
Sections [101] to [148] represent zones 1 through 48. This
feature defines the type of zone, its partition assignment and
the zone's options.
Zone Definitions
] of the
0
- Disabled (Default)
1
- Entry Delay 1
2
- Entry Delay 2
3
- Entry Delay 3
4
- Entry Delay 4
5
- Follow
6
- Instant
7
- 24Hr Buzzer
] of
Zone Partition Assignment
1- Zone Assigned to Partition1 (Default)
2- Zone Assigned to Partition 2
3- Zone Assigned to Partition 3
4- Zone Assigned to Partition 4
Input#
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
__/__/__
Zone Options
[1] Auto Zone Shutdown Enabled
8
- 24Hr Burglary
[2] Bypass Enabled (Default)
[3] Stay Zone
9
- Delayed 24Hr Fire
[4] Force Zone
A
- Standard 24Hr Fire
B
- Stay Delay 1
[5]
C
- Stay Delay 2
off
D
- Stay Delay 3
off
E
- Stay Delay 4
on
on
[7] Intellizone
[8] Delay before transmission
Section
Define
Assign
[101]
1 2 3 4 5 6 7 8
___
___
[102]
1 2 3 4 5 6 7 8
___
___
[103]
1 2 3 4 5 6 7 8
___
___
[104]
1 2 3 4 5 6 7 8
___
___
[105]
1 2 3 4 5 6 7 8
___
___
[106]
1 2 3 4 5 6 7 8
___
___
[107]
1 2 3 4 5 6 7 8
___
___
[108]
1 2 3 4 5 6 7 8
___
___
[109]
1 2 3 4 5 6 7 8
___
___
[110]
1 2 3 4 5 6 7 8
___
___
[111]
1 2 3 4 5 6 7 8
___
___
[112]
1 2 3 4 5 6 7 8
___
___
[6]
Zone Alarm Type
off
Steady Alarm
on
Pulsed Alarm
off
Silent Alarm
on
Report Only
Zone Options