The control panel deactivates an activated PGM in one of two ways (also see sections [502] and [503]):
Section [502]: Option OFF = Follow Activation Event:
If the first digit of the PGM Activation Event is set at 1, 2, 3, 4, or 7, the PGM will remain activated until the PGM Activation
Event has ended. It will ignore the PGM Deactivation Event. If the first digit of the PGM Activation Event is set at 8, 9, A, B, C,
D, E, or F, the PGM will remain activated until the PGM Deactivation Event occurs.
Section [502]: Option ON = Follow PGM Delay Timer:
After activating the PGM, the control panel will start the PGM delay timer and the PGM will deactivate only when the PGM
delay timer has elapsed regardless of the PGM Deactivation Event.
Section
[400]
PGM1 Activation Event
[401]
PGM1 Deactivation Event
[402]
PGM2 Activation Event
[403]
PGM2 Deactivation Event
[404]
PGM3 Activation Event
[405]
PGM3 Deactivation Event
[406]
PGM4 Activation Event
[407]
PGM4 Deactivation Event
[408]
PGM5 Activation Event
[409]
PGM5 Deactivation Event
Second
First Digit
Digit
0 = PGM Disabled
Note 1*
1 = Status 1
Note 1*
2 = Status 2
Note 1*
3 = Status 3
NOTE 1*:
0 = Occurs in all partitions enabled in the system (see section [500]).
1 = Partition 1
3 = Partition 3
2 = Partition 2
4 = Partition 4
8 = Occurs in at least one partition enabled in the system.
† : If you select a group and set all options to OFF, all users/zones/selections of that group will be enabled (result is "ANY" of
that group). For example, if you select A0 and set all 8 options to OFF, the PGM will activate/deactivate whenever a user
between 1 and 8 arms the system.

Programmable Outputs

PGM
1
2
N/A
N/A
N/A
Any Arming
Force
Method
Arm
Ready
Exit Delay
Status
Intellizone
Fire Delay
Digiplex DGP-848
Event Group
Event Group
(First Digit)
(Second Digit)
___
___
___
___
___
___
___
___
___
___
Feature Select Programming †
3
4
N/A
N/A
Stay
Instant
Arm
Arm
(until alarm is
cancelled)
Entry Delay
Trouble
Memory
Auto Arm
N/A
Any Tamper
Delay
- 14 -
Programming Guide
Event Selection
(on/off)†
___
1
2
3
___
1
2
3
___
1
2
3
___
1
2
3
___
1
2
3
___
1
2
3
___
1
2
3
___
1
2
3
___
1
2
3
___
1
2
3
5
6
N/A
N/A
N/A
Strobe
Silent
Audible
Alarm
Alarm
(until alarm is
(until alarm is
cancelled or
cancelled or
bell is cut off)
bell is cut off)
Alarm
Zone
Master or
Bypassed
Installer
(armed or not)
Programming
Zone Low
Fire Loop
Battery
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
4
5
6
7
8
7
8
N/A
Fire Alarm
(until alarm is
cancelled or
bell is cut off)
Keypad
Lockout
Zone
Supervision