Contact ID Report Code List
If using the Ademco Contact ID format, key in the 2-digit hexadecimal value (PROG. VALUE) to program the desired report
codes into sections [600] to [718].
CID#
Reporting Code
MEDICAL ALARMS - 100
100
Medical Alarm
101
Pendant Transmitter
102
Fail to Report In
FIRE ALARMS - 110
110
Fire Alarm
111
Smoke
112
Combustion
113
Water Flow
114
Heat
115
Pull Station
116
Duct
117
Flame
118
Near Alarm
PANIC ALARMS - 120
120
Panic Alarm
121
Duress
122
Silent
123
Audible
BURGLAR ALARMS - 130
130
Burglary
131
Perimeter
132
Interior
133
24-Hour
134
Entry/Exit
135
Day/Night
136
Outdoor
137
Tamper
138
Near Alarm
GENERAL ALARMS - 140
140
General Alarm
141
Polling Loop Open
142
Polling Loop Short
143
Expansion Module Failure
144
Sensor Tamper
145
Expansion Module Tamper
24-HOUR NON-BURGLARY - 150 & 160
150
24-Hour Non-Burglary
151
Gas Detected
152
Refrigeration
153
Loss of Heat
154
Water Leakage
155
Foil Break
156
Day Trouble
157
Low Bottled Gas Level
158
High Temp
159
Low Temp
161
Loss of Air Flow
FIRE SUPERVISORY - 200 & 210
200
Fire Supervisory
201
Low Water Pressure
202
Low CO2
203
Gate Valve Sensor
Prog.
CID#
Reporting Code
Value
204
Low Water Level
01
205
Pump Activated
02
206
Pump Failure
03
SYSTEM TROUBLES - 300 & 310
300
System Trouble
04
301
AC Loss
05
302
Low System Battery
06
303
RAM Checksum Bad
07
304
ROM Checksum Bad
08
305
System Reset
09
306
Panel Program Changed
0A
307
Self-Test Failure
0B
308
System Shutdown
0C
309
Battery Test Failure
310
Ground Fault
0D
SOUNDER/RELAY TROUBLES - 320
0E
320
Sounder Relay
0F
321
Bell 1
10
322
Bell 2
323
Alarm Relay
11
324
Trouble Relay
12
325
Reversing
13
SYSTEM PERIPHERAL TROUBLES - 330 & 340
14
330
System Peripheral
15
331
Polling Loop Open
16
332
Polling Loop Short
17
333
Exp. Module Failure
18
334
Repeater Failure
19
335
Local Printer Paper Out
336
Local Printer Failure
1A
COMMUNICATION TROUBLES - 350 & 360
1B
350
Communication
1C
351
Telco Fault 1
1D
352
Telco Fault 2
1E
353
Long Range Radio
1F
354
Fail to Communicate
355
Loss of Radio Supervision
20
356
Loss of Central Polling
21
PROTECTION LOOP TROUBLES - 370
22
370
Protection Loop
23
371
Protection Loop Open
24
372
Protection Loop short
25
373
Fire Trouble
26
SENSOR TROUBLES - 380
27
380
Sensor Trouble
28
381
Loss of Super. -RF
29
382
Loss of Super. - RPM
2A
383
Sensor Tamper
384
RF xmtr. Low Battery
2B
OPEN/CLOSE - 400
2C
400
Open/Close
2D
401
O/C by User
2E
402
Group O/C
Digiplex DGP-848
- 38 -
Prog.
CID#
Value
2F
403
30
404
31
405
406
32
407
33
408
34
409
35
REMOTE ACCESS - 410
36
411
37
412
38
413
39
414
3A
415
3B
ACCESS CONTROL - 420
3C
421
422
3D
SOUNDER RELAY DISABLES - 520
3E
520
3F
521
40
522
41
523
42
524
525
43
COMMUNICATION DISABLES - 550 & 560
44
551
45
552
46
47
570
48
571
49
572
573
4A
574
4B
TEST/MISC. - 600
4C
601
4D
602
4E
603
4F
604
50
605
606
51
607
52
621
53
622
54
623
624
55
625
56
626
57
627
58
628
59
631
5A
5B
5C
Programming Guide
Reporting Code
Automatic O/C
Late to O/C
Deferred
Cancel
Remote Arm/Disarm
Quick Arm
Keyswitch O/C
Callback Request Made
Success - Download Access
Unsuccessful Access
System Shutdown
Dialer Shutdown
Access Denied
Access Report By User
Sounder/Relay Disabled
Bell 1 Disable
Bell 2 Disable
Alarm Relay Disable
Trouble Relay Disable
Reversing Relay Disable
Dialer Disabled
Radio xmitter Disabled
BYPASSES - 570
Zone Bypass
Fire Bypass
24-Hour Zone Bypass
Burg. Bypass
Group Bypass
Manual Trigger Test
Periodic Test Report
Periodic RF Xmission
Fire Test
Status Report to Follow
Listen-in to Follow
Walk Test Mode
Event Log Reset
Event Log 50% Full
Event Log 90% Full
Event Log Overflow
Time/Date Reset
Time/Date Inaccurate
Program Mode Entry
Program Mode Exit
Exception Schedule Change
Prog.
Value
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents