Figure 5-11:
A. FODO1 and DI1/FODO6 - shared common ground - Type 4 CPU Module (Group 1)
B. FODO2, FODO3 , FODO4 and FODO5 - shared common ground - Type 4 CPU Module (Group 2)
5.4
Configure frequency outputs
The Frequency Outputs allows you to configure the available frequency outputs for the
meter. If you previously configured one or more Frequency/Digital outputs make
selections for the following parameters.
Content:
•
•
Direction:
•
Operations manual
CPU Module - Frequency/Digital outputs common ground - Type 4
Valid outputs are based on Uncorrected (Actual) flow rates or on Corrected
(Standard) flow rates. If pressure or temperature is set to Not used, or the Base
condition correction is cleared on the Startup Page, the Corrected (Standard) option
will not be available.
Daniel Gas Ultrasonic meters will also allow you to set the outputs for Average Flow
Velocity, Average Sound Velocity, Energy Rate, and Mass Rate.
Reverse: The output only reports flow in the reverse direction. For frequency
outputs, Phase B of the output is 90 degrees out of phase with Phase A.
Configurations
57