POWER ON LOAD

Power on the load in each zone is read in variable Ld.P and the corresponding energy value in variables Ld.E1 and Ld.E2.
These energy values show the value accumulated since the first power on or since the last reset (commands at bits 114 and
115); non-volatile memory is updated at power off.
Load impedance in each zone is read in variable Ld.I.
If zone 1 has a 3-phase load, variable Ld.P.t shows power and Ld.I.t total impedance, the corresponding energy value in va-
riables Ld.E1.t and Ld.E2.t.
Note that for loads such as IR lamps, impedance can vary greatly based on the power transferred to the load.
719*
Ld. P
720
Ld. P . t
749*
Ld. I
750
Ld. I . t
531*
Ld. E 1
541
Ld. E 1. t
510*
Ld. E 2
541
Ld. E 2. t
Azzeramento
114*
bit
Ld. E 1
Azzeramento
115*
bit
Ld. E 2
FUNCTIONAL DIAGRAM
Single-phase load
RMS voltage
value
on load (Ld.V)
RMS current
value
on load (Ld.A)
80963B_MSW_GFW_11-2012_ENG
R
Power on load
R
Power on load 3-phase
R
Impedance on load
R
Impedance onload 3-phase
Energy on load
R
R
Energy on 3-phase load
R
Energy on load
Energy on 3-phase load
R
OFF = -
R/W
ON = Reset Ld.E1
OFF = -
R/W
ON = Reset Ld.E2
X
Ld.V/Ld.A
Data in DWORD (32 bit) format
Data in DWORD (32 bit) format
Data in DWORD (32 bit) format
Data in DWORD (32 bit) format
Variable Ld.P
X CoS.F
active power [kW]
Variable Ld.I
impedance [ohm]
Variables Ld.E1 and Ld.E2
by time
energy [kwh
21