Multi-Fault-Detection Holdtime - Alaxala AX3640S Software Manual

Configuration command reference vol. 1 for version 11.7
Table of Contents

Advertisement

multi-fault-detection holdtime

This is used in a multi-ring configuration with shared links. This command sets the hold time
before the shared nodes at both ends of a shared link determine that multiple faults occurred when
the shared link monitoring rings did not receive any sent multi-fault monitoring frames.
Syntax
To set or change information:
multi-fault-detection holdtime <milli seconds>
To delete information:
no multi-fault-detection holdtime
Input mode
(config-axrp)
Parameters
<milli seconds>
Specifies the hold time in milliseconds until a multi-fault monitoring frame is received.
1.
Default value when this parameter is omitted:
This parameter cannot be omitted.
2.
Range of values:
1000 to 300000
Default behavior
The reception hold time for multi-fault monitoring frames is set to 6000 milliseconds.
Impact on communication
None
When the change is applied:
The change is applied immediately after setting values are changed.
Notes
1.
The multi-fault monitoring functionality cannot be used concurrently with a Spanning Tree
Protocol or GSRP that uses a virtual link on the same switch.
2.
For the
multi-fault-detection holdtime
multi-fault-detection interval
equal to or less than the value specified for the
for the opposing node, multiple faults will be detected.
3.
If the hold time elapses, the shared nodes determine that multiple faults occurred in the shared
link monitoring rings, and perform a failure handling process.
Related commands
None
command, set a value larger than the value of the
command for the opposing node. If you specify a value
multi-fault-detection interval
14. Ring Protocol
command