Vrrp Timers Non-Preempt-Swap - Alaxala AX3640S Software Manual

Configuration command reference vol. 1 for version 11.7
Table of Contents

Advertisement

28. VRRP

vrrp timers non-preempt-swap

Sets the switchback suppression time to be applied when switchback processing is performed
while automatic switchbacks are suppressed.
Syntax
To set or change information:
vrrp <vrid> timers non-preempt-swap <seconds>
To delete information:
no vrrp <vrid> timers non-preempt-swap
Input mode
(config-if)
Parameters
<vrid>
Specifies the virtual router ID.
1.
Default value when this parameter is omitted:
This parameter cannot be omitted.
2.
Range of values:
1 to 255
<seconds>
Specify the switchback suppression time (in seconds) to be applied when switchback
processing is performed while automatic switchbacks are suppressed.
1.
Default value when this parameter is omitted:
This parameter cannot be omitted.
2.
Range of values:
1 to 65535
Default behavior
The switchback suppression time to be applied when switchback processing is performed while
automatic switchbacks are suppressed is set to 0 second. Switchbacks are not suppressed.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
None
Related commands
vrrp preempt