4.11 S
TOP
It is the output frequency at which the DC-braking is applied.
4.12 S
TART
DC-brake is activated when the start command is given. This parameter de-
fines the time of the DC-braking. After the brake is released, the output fre-
quency increases according to the set start function by par. 2.2.
Par 4.9
9
DC
CURRENT FREQUENCY
DC
CURRENT TIME
DC-brakin g
current
Pa r4.12
RUN
STOP
Figure 9.10: DC braking time at start