Vacon 10 Complete User's Manual page 73

Frequency converter
Hide thumbs Also See for 10:
Table of Contents

Advertisement

70
vacon
Selection
number
1
Output
FWD
frequency
Set
frequency
0 Hz
Set
frequency
REV
Run enable
Ctrl signal 1
Ctrl signal 2
Keypad
stop button
Figure 9.4: Start/Stop logic, selection 1
Explanations
1
Control signal (CS) 1 actives causing the
output frequency to rise. The motor runs
forward.
2
CS2 inactivates causing the frequency to
drop to 0.
3
CS1 inactivates causing the output fre-
quency to rise again. The motor runs
forward.
4
Run enable signal is set to FALSE, which
drops the frequency to 0. The run enable
signal is configured with par. 5.7.
5
Start attempt with CS1 is not successful
because Run enable signal is still
FALSE.
9
Selection name
CS1:Forward(edge)
CS2:Inverted stop
1
2
3
parameter descriptions
Note
4
5
6
7
6
CS1 activates and the motor accelerates
(FWD) towards the set frequency
because the Run enable signal has been
set to TRUE.
7
Keypad stop button is pressed and the
frequency fed to the motor drops to 0.
8
CS1 activates causing the output fre-
quency to rise again. The motor runs
forward.
9
CS2 inactivates causing the frequency to
drop to 0.