Vacon 10 Complete User's Manual page 53

Frequency converter
Hide thumbs Also See for 10:
Table of Contents

Advertisement

50
vacon
8.1 Quick setup parameters (Virtual menu, shows when par. 17.2 = 1)
Code
Parameter
Motor nominal
P1.1
voltage
Motor nominal
P1.2
frequency
Motor nominal
P1.3
speed
Motor nominal
P1.4
current
Motor cos
P1.5
(Power Factor)
i
Current limit
P1.7
i
Torque boost
P1.15
Remote control
i
P2.1
place 1 selection
i
Start function
P2.2
i
Stop function
P2.3
Min frequency
P3.1
Max frequency
P3.2
Remote Control
Place 1 frequency
i
P3.3
reference selec-
tion
i
P3.4
Preset speed 0
i
P3.5
Preset speed 1
i
P3.6
Preset speed 2
i
P3.7
Preset speed 3
Table 8.1: Quick setup parameters
8
Min
Max
Unit
180
690
30,00 320,00
30
20000
rpm
0,2 x
2,0 x
I
I
Nunit
Nunit
0,30
1,00
0,2 x
2.0 x
I
I
Nunit
Nunit
0
1
0
1
1
0
1
0
0,00
P3.2
P3.1 320,00
1
6
P3.1
P3.2
P3.1
P3.2
P3.1
P3.2
P3.1
P3.2
Tel. +358 (0)201 2121 • Fax +358 (0)201 212205
Default
ID
V
Varies
110
50,00 /
Hz
111
60,00
1440 /
112
1720
I
A
113
Nunit
0,85
120
1.5 x
A
107 Maximum motor current
I
Nunit
0
109
0
172
0
505
0
506
Hz
0,00
101 Minimum freq reference
50,00 /
Hz
102
60,00
4
117
Hz
5,00
124
Hz
10,00
105
Hz
15,00
106
Hz
20,00
126
parameters
Note
Check rating plate on the
motor.
Check rating plate on the
motor.
Default applies for a 4-
pole motor.
Check rating plate on the
motor.
Check rating plate on the
motor.
0 = Not used
1 = Used
0 = I / O terminal
1 = Fieldbus
0 = Ramp
1 = Flying start
0 = Coasting
1 = Ramp
Maximum freq refer-
ence
1 = Preset Speeds 0-7
2 = Keypad
3 = Fieldbus
4 = AI1
5 = AI2
6 = PI
Activated by digital
inputs
Activated by digital
inputs
Activated by digital
inputs
Activated by digital
inputs

Advertisement