5.2 Malfunctions

Malfunctions can be organised in five
categories:
1. Permanent malfunctions (indicated
as >F<). This malfunction cannot be
fixed automatically, the gas fire is
blocked for 24 hours (except for the
error code 02F).
2. Recovering malfunctions (indicated
as >ALARM< or >A<). Malfunction
that can recover automatically, if the
cause has been detected and fixed.
3. Communication malfunctions (indi-
cated as >E<). Malfunctions in the
communication connection between
the fireplace and the remote control
- these malfunctions can be fixed au-
tomatically when the remote control
is placed closer to the technical unit
of the fireplace.
Press 1 x
.
4. Signal malfunctions (indicated as
>NOLK 0 or 1< or a flashing RF icon
). The remote control does not
communicate with the fireplace. This
malfunction
cannot be fixed automatically.
5. Fireplace failure. The automatic
burner relay requires a "time-out"
every 24 hours (according to current
inspection regulations). During this
"time-out", all applications of the
automatic burner relay are tested.
The fireplace is automatically swit-
ched off and stays down, until it is
turned on again manually.
28
5.2.1 Removing or resetting a
malfunction.
The automatic burner relay is equip-
ped with a safety setting per gas type
for the automatic ignition attempts.
Natural gas (G20, G25) has three auto-
matic ignition attempts and propane or
butane gas (G30) only has one ignition
attempt to ignite the burner. Should
the automatic ignition attempt(s) fail,
error code 08A and >ER< (Error) ap-
pear. This error code can be unlocked
and removed twice using the remote
control, before a 24-hour shut down is
initiated (error code 08F).
Carry out the following steps to unlock
the fireplace;
1. Press
approximately five times,
after which the "A" code disappears.
2. Check if the gas valve is open.
3. Inspect if the ionisation pen is unob-
structed by looking through the
glass.
4. Initiate the new ignition atempt.
Press
, until >OK< flashes in the
top left corner of the display.
5. You can repeat step 1-4 once.
6 If error code 08F appears you have
to wait 24 hours before you can
reattempt to ignite the gas fire.
The waiting time must be respected,
also after a power interruption.