Kalfire G Series User Instructions

Balanced-flue gas fires
Hide thumbs Also See for G Series:

Advertisement

User
instructions
EN
BALANCED-FLUE GAS FIRES
DON'T COMPROMISE.

Advertisement

Table of Contents
loading

Summary of Contents for Kalfire G Series

  • Page 1 User instructions BALANCED-FLUE GAS FIRES DON’T COMPROMISE.
  • Page 3 Balanced-flue gas fires Kalfire G G60/48F, G65/44C, G70/44S G80/48F, G85/44C, G90/44S G100/41F, G105/37C, G110/37S G120/41F, G125/37C, G130/37S G160/41F, G165/37C, G170/37S for gas type: G20, G25 and G30 Balanced-flue gas fires Kalfire GP GP60/59F, GP65/55C, GP70/55S GP60/79F, GP65/75C, GP70/75S GP75/59F, GP80/55C, GP85/55S...
  • Page 5: Table Of Contents

    Contents General information 4.12 Setting the Natural Foreword Spark Generator Pictograms 4.13 Fill the Natural Warranty Spark Generator Compatibility iMatch interface 9 4.14 Configure the iMatch app 4.15 iMatch app settings Safety 4.16 Resetting the iMatch Safety instructions for interface decorative elements 4.17 Using the iMatch app...
  • Page 7: General Information

    If the gas fire is not installed correctly, Installation Manual accompanies this all warranty and/or damage claims User Instructions. The user instructions against Kalfire will be declared null and should remain in the vicinity of the gas void. fire so that they are readily available for fireplace users.
  • Page 8: Pictograms

    Any risk is fully for the account Warranty conditions 1. The warranty period for Kalfire gas of the user. appliances amounts to two years from the procurement date, that Copyright @ 2018 Kalfire B.V. Geloërveldweg 21, Belfeld, must be clearly legible on the proof The Netherlands of purchase.
  • Page 9: Compatibility Imatch Interface

    9. Should the technical fitter approved 6. Should deviation from the Kalfire specifications have occurred in any by Kalfire be unable to rectify the problem covered by the warranty, way or form during configuration of then he is entitled upon his own...
  • Page 10 Only after installation of the interface can compatibility be confirmed. Kalfire accepts no liability for the non-functioning, or insufficient functioning, of the iMatch interface as a consequence of the cause described...
  • Page 11: Safety

    100 cm (depending on the Kalfire GP mo- from the fireplace. If a fireguard is del). used, this distance must be at least...
  • Page 12: Three Safety Measures For The Gas Fire

    If you notice fumes or gas, take the fol- lowing precautions: 20° 20° 1. Switch off the gas fire. 40 cm 2. Close the main gas valve. 30 cm 3. Open windows and doors. 4. Advise an approved installer of the 100 cm issue.
  • Page 13 2. 24 hour security The appliance will stay in a blocked position if no flame is detected after three automatic ignition attempts (error code 08A). The block will take effect after one ignition attempt with gas type G30. This block can twice be unlocked manually with the remote control.
  • Page 14: Description

    Prestige burner. The following sections describe the gas fire: The Kalfire G with a 3D burner ge- - Description of the gas fire. nerates an elongated and horizontal flame pattern, well suited to a modern 3.1 Gas fire description...
  • Page 15 into that system. The gas fire can also be controlled by the iMatch App on a smartphone or tablet. This is only pos- sible if the gas fire is equipped with the optional iMatch interface, that serves as the receiver.
  • Page 16: Operation

    4. Operation 3. Place the two batteries on the com- partment floor as indicated. The upcoming sections provide infor- 4. Close the compartment cover. mation about the use of the gas fire: 5. Press the centre button and the - Replacing the batteries display will light up.
  • Page 17: Setting Day And Time

    Buttons: a. + and - buttons b. Left button and right c. Centre button d. On/off button e. Parameter configuration button P 4.3 Setting day and time Setting day and time. Carry out the following steps to change the day and time settings: 1.
  • Page 18: Switching The Appliance On And Off

    3. Walk around the appliance at a dis- flame intensity can also be displayed by tance of 3 to 4 metres to measure the flame intensity indicator. the RFCK. If the RFCK shows a value The ECO mode has a modulating effect of 4, the transmission strength of the on flame intensity (higher or lower).
  • Page 19: Setting The Flame Intensity

    4.8 Setting the flame intensity by “TCOM” (temperature comfort). thermostat TCOM indicates the maximum The remote control measures the temperature during all set time temperature and the flame intensity is segments. 5. Set the desired temperature with the modulated accordingly. To ensure an accurate temperature reading, make + or - buttons at increments of 0.5°C.
  • Page 20: Programme Choice For A

    at identical switch-on times. desired “P” programme is displayed. 17. Press P to exit the programme. 3. Wait until the home screen appears. 18. The icons on the remote 4.11 Activating/deactivating control indicate that the time seg- the hybrid LED lighting and ments have been programmed.
  • Page 21: Setting The Natural Spark Generator

    1. Press the forward right button 3. Select the Wi-Fi network named access the Natural Spark Generator “Kalfire”. programme. 4. Open the iMatch app. 2. At the top of the screen, the word 5. Click on “Settings” in the top right “SP0”...
  • Page 22: Imatch App Settings

    LED start flashing rapidly (approxi- 12. Wait 40 seconds while the wizzard is mately 15 seconds). shutting down and the Kalfire 3. Wait for the iMatch interface to logo becomes visible. reboot. 13. Reconnect with your Wi-Fi network (in most cases happens automati- cally).
  • Page 23: Using The Imatch App Through The Imatch Interface

    not adjustable. 4.17 Using the iMatch app through 4. Heating mode: Press “hand control- the iMatch interface led” once in the middle of the circle. The gas fire can be controlled by using Now select the heating mode Eco or the iMatch app, if the iMatch inter- face is connected to your local Wi-Fi network.
  • Page 24: Maintenance

    1%. This varnish is available at Kalfire. To prevent damage to these coatings, it is important that you carefully comply 5.1.1 Cleaning the (standard) to the following cleaning instructions.
  • Page 25 • the glass. This can lead to permanent Carefully clean the glass: use suffi- contamination. cient moisture, avoid pressure and • Clean the glass after the first use of rub the substance from top to bot- the fireplace and clean the glass re- tom, to prevent cleaning detergent gularly in the initial period.
  • Page 26: Door Dismantling And Assembly

    5.1.3 Door dismantling and assembly Step 3: Next, grip the door by the de- (corner and three­sided signated handles. Slightly lift the door appliances) with glass window out of the rabbet, Door removal move the entire door slightly to the left WARNING: Wear (rubber) gloves to or right (corner fireplace) and carefully prevent stains on the glass.
  • Page 27: Door Dismantling And Assembly (Front And Tunnel Fireplaces)

    5.1.4 Door dismantling and Step 3: Push the metal cover strip in left assembly (front and tunnel or right. fireplaces) Door removal WARNING: Wear (rubber) gloves to prevent stains on the glass. Step 1: Move the metal cover strips up from the upper side.
  • Page 28: Malfunctions

    5.2 Malfunctions 5.2.1 Removing or resetting a malfunction. Malfunctions can be organised in five categories: The automatic burner relay is equip- 1. Permanent malfunctions (indicated ped with a safety setting per gas type as >F<). This malfunction cannot be for the automatic ignition attempts. fixed automatically, the gas fire is Natural gas (G20, G25) has three auto- blocked for 24 hours (except for the...
  • Page 29: Error Codes Imatch Remote Control

    5.2.2 Error codes iMatch remote control Error code Cause Solution Entire display Flat battery Replacing battery. flashing Low battery Replacing battery. NOLK 0 in the middle Bedienings- Druk kort op >NOLK< zal nu linksboven in het display of the fout verschijnen.
  • Page 30 Error code Cause Solution Tempera- Turn off the fireplace for approximately 30 minutes. ture of the Then turn on the fireplace. circuit board In case the error reappears, there is insufficient is too high ventilation in the chamber of the fireplace. No mains voltage supply...
  • Page 31 Error code Cause Solution A flame is visible during ignition 1. Check if the ionisation pen is completely unobstructed by looking into the fireplace. Check if the plug in the technical box is correctly connected.See Wiring diagram on page 36. Check the connection with the ionisation pen and whether there are damages to the ionisation cable.
  • Page 32 Error code Cause Solution Problem Check whether the gas valve is open. with Measure the gas pressure at the gas valve intake. regulating This must be > 20 mbar or with a G30(B/P) > 40 mbar. the gas Measure the burner pressure with the measurement valve, nipple behind the gas valve.
  • Page 33: Error Code Imatch Interface

    No power supply on the Natural Spark Generator -> check whether the Natural Spark Generator has been connected correctly. See: Wiring diagram on page 36 . • Natural Spark Generator pump / coil is defect -> contact your dealer or Kalfire.
  • Page 34: Appendices

    A. Appendices The following sections contain appendices attached to the gas fire: - Product card - Wiring diagram - Certificate of compliance...
  • Page 35: Product Card

    A.1 Product card (in conformance with (EU) 2015/1186 Appendix IV) Model Kalfire G60/48F Kalfire G65/44C Kalfire G70/44S 6.0 kW 84.0% 74.3% Kalfire G60/48F Kalfire G65/44C Kalfire G70/44S 5.8 kW 85.3% 80.0% Kalfire G60/48F Kalfire G65/44C Kalfire G70/44S G30 - 30 mbar 5.5 kW...
  • Page 36: Wiring Diagram

    A.2 Wiring diagram Wiring diagram Natural Spark Generator in the technical unit. Fig. 14: Wiring diagram HCB only applicable in hybrid mode and/or Natural Spark Generator.
  • Page 37: Certificate Of Compliance

    Kalfire B.V. Geloërveldweg 21 NL – 5951 DH, Belfeld Certifies that the following Kalfire appliances, model gas fire: Kalfire GP60/59F, GP65/55C, GP70/55S, Kalfire GP60/79F, GP65/75C, GP70/75S Kalfire GP75/55F, GP80/55C, GP85/55S, Kalfire GP80/54T, GP85/50R Kalfire GP105/59F, GP110/55C, GP115/55S, Kalfire GP105/79F, GP110/75C, GP115/75S...
  • Page 40 Geloërveldweg 21 info@kal-fire.nl 5951 DH Belfeld KALFIRE.COM DON’T COMPROMISE.