Malfunctions; Removing Or Resetting A Malfunction - Kalfire G Series Installation Instructions Manual

Balanced-flue gas fires
Hide thumbs Also See for G Series:
Table of Contents

Advertisement

7.2 Malfunctions

Malfunctions can be organised in five categories:
1. Permanent malfunctions (indicated as >F<). This
malfunction cannot be fixed automatically, the gas fire is
blocked for 24 hours (except for the error code 02F).
2. Recovering malfunctions (indicated as >ALARM< or >A<).
Malfunction that can recover automatically, if the cause has
been detected and fixed.
3. Communication malfunctions (indicated as >E<).
Malfunctions in the communication connection between
the fireplace and the remote control - these malfunctions
can be fixed automatically when the remote control is
placed closer to the technical unit of the fireplace.
Press 1 x
.
4. Signal malfunctions (indicated as >NOLK 0 or 1< or
a flashing RF icon
). The remote control does not
communicate with the fireplace. This malfunction
cannot be fixed automatically.
5. Fireplace failure. The automatic burner relay requires a
"time-out" every 24 hours (according to current inspection
regulations). During this "time-out", all applications of
the automatic burner relay are tested. The fireplace is
automatically switched off and stays down, until it is
turned on again manually.
30

7.2.1 Removing or resetting a malfunction.

The automatic burner relay is equipped with a safety setting
per gas type for the automatic ignition attempts. Natural gas
(G20, G25) has three automatic ignition attempts and propane
or butane gas (G30) only has one ignition attempt to ignite the
burner. Should the automatic ignition attempt(s) fail, error code
08A and >ER< (Error) appear. This error code can be unlocked
and removed twice using the remote control, before a 24-hour
shut down is initiated (error code 08F).
Carry out the following steps to unlock the fireplace;
1. Press
approximately five times, after which the "A"
code disappears.
2. Check if the gas valve is open.
3. Inspect if the ionisation pen is unobstructed by looking
through the glass.
4. Initiate the new ignition attempt. Press
flashes in the top left corner of the display.
5. You can repeat step 1-4 once.
6
If error code 08F appears you have to wait 24 hours before
you can reattempt to ignite the gas fire. The waiting time
must be respected, also after a power interruption.