13 | Lap Trigger
13.1.6 Lap trigger presettings

13.2 Counting outing/laps/fragments

92 / 108
Lap trigger diagnosis scheme
When the reset buttons on the diagnosis page are activated, these values are used.
Functionality
– Power ON: system + measurement is initialized but not yet started
– Global start condition fulfilled: recording starts
– Reception of valid lap trigger: recording of lap completed, new lap starts
– Power OFF or Global start condition not fulfilled: recording of lap completed, system
shutdown
The system is counting:
Outing:
– The outing counter is incremented with each power cycle when at least one valid lap
(not by forced lap trigger) was recorded
Lap:
– Leaving the pits to lap trigger
– Lap trigger to lap trigger
– Enforced lap trigger (see Distance based forced trigger)
Fragment:
– Test bench operation
– Power cycle on track or box (e.g. engine stalled)
– File fragmentation size [MB], time [sec]